Updated on 2025-01-14 GMT+08:00

Error Codes

If an error code starting with APIGW is returned after you call an API, rectify the fault by referring to the instructions provided in API Gateway Error Codes.

Status Code

Error Codes

Error Message

Description

Solution

400

LTS.0009

Failed to validate the request body.

Parameter verification failed.

Modify request parameters based on the returned error information and try again.

400

LTS.0010

The system encountered an internal error

An internal error occurred

An internal error occurred in LTS. Contact technical support.

400

LTS.0201

The log group is not existed

Failed to create the log stream because the associated log group does not exist.

Check whether the ID of the log group is correct.

400

LTS.0208

Log stream is associated by transfer

The log stream does not exist.

Check whether the log stream to be deleted exists.

400

LTS.0301

'*' and '?' not allowed as first character

Asterisks (*) and question marks (?) are placed in the middle or at the end of a keyword.

Check the keywords field based on the error information.

400

LTS.2001

Failed to create alarm rule

Creation error.

Check whether the project ID is correct.

400

LTS.2002

Failed to delete alarm rule

Deletion error.

Check whether the database or network connection is normal.

400

LTS.2003

Failed to update alarm rule

Modification error.

Abnormal connection to the database. Check the database instance status.

400

LTS.2004

The size of alarm rule has exceed the limit: 200

The number of alarm rules cannot exceed 200.

Delete existing alarm rules that are no longer used.

400

LTS.2005

The parameter is incorrect

Incorrect parameter.

Correct the parameter based on the returned error information.

400

LTS.2006

Alarm rule name has already exist

The alarm rule name already exists.

Use another alarm rule name.

400

LTS.2007

Alarm rule not exist

The alarm rule does not exist.

Check whether the alarm rule exists.

400

LTS.2008

Find Alarm rule failed

Failed to query the alarm rule.

Check whether the database or network connection is normal.

400

LTS.2009

User must have SMN service authority

You must have the permissions on SMN.

Acquire the permissions on SMN.

400

LTS.2010

Topics cannot be empty

The SMN topic cannot be empty.

Check whether the SMN topic is empty.

400

LTS.2011

Alarm rule invalid query frequency or invalid cron expression

Invalid query frequency or cron expression.

Check the query frequency or cron expression.

400

LTS.2012

The query time range cannot be larger than 1 hour when the query frequency is less than every 5 minutes.

The query time range cannot be larger than 1 hour when the query frequency is less than every 5 minutes.

Check the query time range and query frequency.

400

LTS.2013

Send Subject Error

Incorrect SMN topic.

Correct the topic based on the error information.

403

LTS.0003

No permission.

Invalid role

Grant the LTS service permission.

403

LTS.0011

Invalid projectId

Invalid project ID.

Ensure that the project ID in the URL is the same as that in the token.

500

LTS.0107

Current user does not have the permission to operate this group

Failed to update the log group.

Abnormal connection to the database. Check the database instance status.