Help Center/ GaussDB(DWS)/ User Guide/ GaussDB(DWS) Cluster O&M/ Viewing GaussDB(DWS) Cluster Alarms/ Alarm Handling/ DWS_2000000031 Active Session Usage in a GaussDB(DWS) Cluster Exceeds the Threshold
Updated on 2025-01-06 GMT+08:00

DWS_2000000031 Active Session Usage in a GaussDB(DWS) Cluster Exceeds the Threshold

Alarm Description

The DMS alarm module generates an alarm if the active session usage in the cluster exceeds the set threshold within a specific time frame and the suppression conditions are not met. The alarm is cleared when the DMS alarm module detects that the active session usage in the cluster is below the threshold.

Alarm Attributes

Alarm ID

Alarm Category

Alarm Severity

Alarm Type

Service Type

Auto Cleared

DWS_2000000031

Management plane alarm

> 90 (Critical); > 80 (Major)

Service alarm

GaussDB(DWS)

Yes

Alarm Changes

Change Type

Change Version

Description

Reason for Change

New

8.2.1.230

New alarm

New alarm

Alarm Parameters

Type

Parameter

Description

Fault Location

Cluster name

Cluster for which the alarm is generated.

Tenant name

Name of the tenant to which the cluster belongs.

Alarm level

Severity of the alarm.

Additional Information

Resource ID

ID of the cluster for which the alarm is generated.

Resource name

Cluster for which the alarm is generated.

First_alarm_time

First occurrence event of an alarm, including the alarm threshold and current value.

Impact on the System

The number of available sessions is insufficient, affecting service execution.

Possible Causes

The value of max_active_statements is too small.

Procedure

  1. Log in to the GaussDB(DWS) console.
  2. On the Alarm page, view the alarms generated in the last seven days.
  3. Choose Dedicated Clusters > Clusters and locate the cluster based on the cluster information in the alarm details.
  4. Click the name of a cluster to view its details. On the cluster details page, click Parameter Modifications, search for max_active_statements in the search box on the right of the parameter list, and change its value.

    Figure 1 Modifying parameters

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None