Alarm Description

This alarm is generated by the DMS alarm module if the session usage in the cluster goes beyond the set threshold within a specific time frame and the suppression conditions are not met. The alarm will be cleared once the session usage in the cluster drops below the threshold.

Alarm Attributes

Alarm ID

Alarm Category

Alarm Severity

Alarm Type

Service Type

Auto Cleared

DWS_2000000030

Management plane alarm

> 90 (Critical); > 80 (Major)

Service alarm

GaussDB(DWS)

Yes

Alarm Changes

Change Type

Change Version

Description

Reason for Change

New

8.2.1.230

New alarm

New alarm

Alarm Parameters

Type

Parameter

Description

Fault Location

Cluster name

Cluster for which the alarm is generated.

Tenant name

Name of the tenant to which the cluster belongs.

Alarm level

Severity of the alarm.

Additional Information

Resource ID

ID of the cluster for which the alarm is generated.

Resource name

Cluster for which the alarm is generated.

First_alarm_time

First occurrence event of an alarm, including the alarm threshold and current value.

Impact on the System

The number of available sessions is insufficient, affecting service execution.

Possible Causes

The value of max_connections is too small.

Procedure

  1. Log in to the GaussDB(DWS) console.
  2. On the Alarm page, view the alarms generated in the last seven days.
  3. Choose Dedicated Clusters > Clusters and locate the cluster based on the cluster information in the alarm details.
  4. Click the cluster name to go to the cluster details page. On the cluster details page, click Parameter Modifications, search for max_connections in the search box on the right of the parameter list, and change its value.

    Figure 1 Modifying parameters

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.