DWS_2500000001 DWS Cluster Schema Usage Exceeds the Threshold
Alarm Description
This alarm is generated by the DMS alarm module if the schema usage in the cluster goes beyond the set threshold within a specific time frame and the suppression conditions are not met. The alarm will be cleared once the schema usage in the cluster drops below the threshold.
Alarm Attributes
| Alarm ID | Alarm Category | Alarm Severity | Alarm Type | Service Type | Auto Cleared | Threshold Alarm Type |
|---|---|---|---|---|---|---|
| DWS_2500000001_OM | Tenant plane | User-defined by threshold (Critical/Major/Minor/Warning) | Quality of service | Data Warehouse Service (DWS) | Yes | Cloud service threshold alarm |
Alarm Parameters
| Type | Parameter | Description |
|---|---|---|
| Location Information | Cluster name | Cluster for which the alarm is generated. |
| Tenant name | Name of the tenant to which the cluster belongs. | |
| Alarm level | Severity of the alarm. | |
| Additional Information | Resource ID | ID of the cluster for which the alarm is generated. |
| Resource name | Cluster for which the alarm is generated. | |
| Node name | Name of the node for which the alarm is generated. | |
| Instance name | Name of the instance for which the alarm is generated. | |
| Database name | Name of the database for which the alarm is generated. | |
| First_alarm_time | Time when an alarm was generated first time. |
Impact on the System
Users cannot create more data in the schema.
Possible Causes
The table data in the schema occupies a large amount of space.
Handling Procedure
- Log in to the DWS console.
- Click the name of the target cluster. In the navigation pane, choose Intelligent O&M.
- Click the O&M Plan tab. Click Add O&M Task.
- Perform the following operations on the Add O&M Task page:
- Select Vacuum for O&M Task.
- Set Scheduling Mode to Auto. DWS automatically scans tables that require VACUUM operation.
- Set Auto to User tables (VACUUM FULL).
- Click Next: Configure Schedule to configure the schedule and Vacuum type. You are advised to select Periodic for Task Type. DWS automatically executes VACUUM in your selected time windows.
For automatic Vacuum O&M tasks, the system uses the VACUUM FULL operation to process user tables. VACUUM FULL holds a level 8 lock, which blocks other transactions. Other transactions will be in lock waiting during VACUUM FULL execution. After 20 minutes, a timeout error is reported. Therefore, do not perform other transactions in the configured time window.
- Click Next: Finish. After you confirm the information, click Finish to submit the request.
Alarm Clearance
After the fault is rectified, manually clear the alarm.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot