Selecting a Table Storage Mode
GaussDB(DWS) supports hybrid row and column storage. When creating a table, you can set the table storage mode to row storage or column storage.
Row storage stores tables to disk partitions by row, and column storage stores tables to disk partitions by column. By default, a table is created in row storage mode. For details about differences between row storage and column storage, see Figure 1.
In the preceding figure, the upper left part is a row-store table, and the upper right part shows how the row-store table is stored on a disk; the lower left part is a column-store table, and the lower right part shows how the column-store table is stored on a disk.
The row/column storage of a table is specified by the orientation attribute in the table definition. The value row indicates a row-store table and column indicates a column-store table. The default value is row. Each storage mode applies to specific scenarios. Select an appropriate mode when creating a table.
Storage Mode |
Benefit |
Drawback |
Application Scenarios |
---|---|---|---|
Row storage |
All the columns of a record are stored in the same partition. Data can be easily inserted and updated. |
All the columns of a record are read after the SELECT statement is executed even if only certain columns are required. |
|
Column storage |
|
|
|
Creating a Row-store Table
For example, to create a row-store table named customer_t1, run the following command:
Creating a column-store table.
For example, to create a column-store table named customer_t2, run the following command:
Table Compression
Table compression can be enabled when a table is created. Table compression enables data in the table to be stored in compressed format to reduce memory usage.
In scenarios where I/O is large (much data is read and written) and CPU is sufficient (little data is computed), select a high compression ratio. In scenarios where I/O is small and CPU is insufficient, select a low compression ratio. Based on this principle, you are advised to select different compression ratios and test and compare the results to select the optimal compression ratio as required. Specify a compressions ratio using the COMPRESSION parameter. The supported values are as follows:
- The valid value of column-store tables is YES, NO, LOW, MIDDLE, or HIGH, and the default value is LOW.
- The valid values of row-store tables are YES and NO, and the default is NO. (The row-store table compression function is not put into commercial use. To use this function, contact technical support.)
The service scenarios applicable to each compression level are described in the following table.
Compression Level |
Application Scenario |
---|---|
LOW |
The system CPU usage is high and the disk storage space is sufficient. |
MIDDLE |
The system CPU usage is moderate and the disk storage space is insufficient. |
HIGH |
The system CPU usage is low and the disk storage space is insufficient. |
For example, to create a compressed column-store table named customer_t3, run the following command:
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.