Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ WAC&AP Alarms/ ALM-303046423 The number of SIPFPM flow tables on the AP reaches the maximum
Updated on 2024-01-25 GMT+08:00

ALM-303046423 The number of SIPFPM flow tables on the AP reaches the maximum

Description

WLAN/4/AP_USER_SIPFPM_FLOW_FULL: OID [oid] The s-ipfpm stream number of the terminal reaches the upper limit. (APMAC=[OPAQUE], APName=[STRING], APID=[INTEGER], StaMac=[OPAQUE], MaxUserSipfpmFlowNum=[INTEGER])

The number of S-IPFPM flows of a STA on an AP exceeded the threshold.

Attribute

Alarm ID

Alarm OID

Alarm Severity

Alarm Type

303046423

1.3.6.1.4.1.2011.6.139.18.1.1.1.14

Warning

Quality of service alarm

Parameters

Name Meaning

OID

Indicates the ID of a MIB object.

APMAC

Indicates the MAC address of an AP.

APName

Indicates the AP name.

APID

Indicates the AP ID.

StaMac

Indicates the MAC address of a STA, which functions as the index for querying its association information.

MaxUserSipfpmFlowNum

Indicates the maximum number of S-IPFPM flows of the STA.

Impact on the System

New flows meeting the iPCA analysis criteria of the STA are not added to the flow table.

Possible Causes

The number of flows for iPCA analysis of the STA exceeds the specifications.

Procedure

  1. Adjust the scope of monitored applications to reduce unimportant applications.

Clearing

After the fault is rectified, the system clears this alarm, removing the need to manually clear it. This alarm will not be displayed on the CurrentAlarms page.