Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ WAC&AP Alarms/ ALM-303046422 The SIPFPM flow table on the AP exceeds the threshold
Updated on 2024-01-25 GMT+08:00

ALM-303046422 The SIPFPM flow table on the AP exceeds the threshold

Description

WLAN/4/AP_SIPFPM_FLOW_OVERLOAD: OID [oid] AP s-ipfpm stream number overload. (APMAC=[OPAQUE], APName=[STRING], APID=[INTEGER], CurSipfpmFlowRate=[INTEGER]%, UpperSipfpmFlowThreshold=[INTEGER]%, LoweSipfpmFlowThreshold=[INTEGER]%)

The number of S-IPFPM flows on an AP exceeded the threshold.

Attribute

Alarm ID

Alarm OID

Alarm Severity

Alarm Type

303046422

1.3.6.1.4.1.2011.6.139.13.1.1.145

Warning

Quality of service alarm

Parameters

Name Meaning

OID

Indicates the ID of a MIB object.

APMAC

Indicates the MAC address of an AP.

APName

Indicates the AP name.

APID

Indicates the AP ID.

CurSipfpmFlowRate

Indicates the current S-IPFPM flow usage.

UpperSipfpmFlowThreshold

Indicates the upper alarm threshold for the S-IPFPM flow usage.

LoweSipfpmFlowThreshold

Indicates the lower alarm threshold for the S-IPFPM flow usage.

Impact on the System

New flows meeting the iPCA analysis criteria on the AP are not added to the flow table.

Possible Causes

The number of flows for iPCA analysis on the AP exceeds 90% of the specifications.

Procedure

  1. Adjust the scope of monitored applications to reduce unimportant applications.

Clearing