Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ WAC&AP Alarms/ ALM-303046424 The SIPFPM flow table on the AC reaches the upper limit
Updated on 2024-01-25 GMT+08:00

ALM-303046424 The SIPFPM flow table on the AC reaches the upper limit

Description

ENTITYTRAP/4/SIPFPM_FLOW_OVERLOAD: OID [oid] The s-ipfpm stream number overload. (Index=[INTEGER], HwEntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", CurSipfpmFlowRate=[INTEGER]%, UpperSipfpmFlowThreshold=[INTEGER]%, LoweSipfpmFlowThreshold=[INTEGER]%)

The number of entries in the S-IPFPM flow table reached the upper limit.

Attribute

Alarm ID

Alarm OID

Alarm Severity

Alarm Type

303046424

1.3.6.1.4.1.2011.5.25.219.2.43.1

Warning

Quality of service alarm

Parameters

Name Meaning

OID

Indicates the ID of a MIB object.

Index

Indicates the entity index.

HwEntityPhysicalIndex

Indicates the physical entity index.

PhysicalName

Indicates the physical entity name.

CurSipfpmFlowRate

Indicates the current S-IPFPM flow usage.

UpperSipfpmFlowThreshold

Indicates the upper alarm threshold for the S-IPFPM flow usage.

LoweSipfpmFlowThreshold

Indicates the lower alarm threshold for the S-IPFPM flow usage.

Impact on the System

New flows meeting the iPCA analysis criteria are not added to the flow table.

Possible Causes

The number of flows for iPCA analysis exceeds 90% of the specifications.

Procedure

  1. Adjust the scope of monitored flows to reduce unimportant flows.

Clearing

After the fault is rectified, the system clears this alarm, removing the need to manually clear it. This alarm will not be displayed on the CurrentAlarms page.