Help Center/ ROMA Connect/ User Guide/ Data Source Management/ Connecting to an ArtemisMQ Data Source
Updated on 2024-05-07 GMT+08:00

Connecting to an ArtemisMQ Data Source

Overview

ROMA Connect can use ArtemisMQ as a data source for data integration tasks. Before using the ArtemisMQ data source, you need to connect it to ROMA Connect.

Prerequisites

Each connected data source must belong to an integration application. Ensure that an integration application is available before connecting a data source, or create one first.

Procedure

  1. Log in to the ROMA Connect console. On the Instances page, click View Console of an instance.
  2. In the navigation pane on the left, choose Data Sources. In the upper right corner of the page, click Access Data Source.
  3. On the Default tab page, select ArtemisMQ and click Next.
  4. Configure the data source connection information.
    Table 1 Data source connection information

    Parameter

    Description

    Name

    Enter a data source name. Using naming rules facilitates future search.

    Encoding Format

    Default: utf-8

    Integration Application

    Select the integration application to which the data source belongs.

    Description

    Enter a brief description of the data source.

    Connection Address

    Enter the IP address and port number of the ArtemisMQ.

    Username

    Enter the username for connecting to ArtemisMQ.

    Password

    Enter the password for connecting to ArtemisMQ.

    SSL Authentication

    Determine whether to use SSL authentication for the connection between ROMA Connect and ArtemisMQ.

    Authentication Mode

    This parameter is mandatory only if SSL Authentication is set to Enable.

    Select the SSL authentication mode.

    • One-way SSL: Only the client (ROMA Connect) authenticates the server (ArtemisMQ).
    • Two-way SSL: The client (ROMA Connect) and server (ArtemisMQ) authenticate each other.

    Trust Store

    This parameter is mandatory only if SSL Authentication is set to Enable.

    This parameter specifies the trust store used by the client during SSL authentication. It must match the private key used by the server.

    Trust Store Password

    This parameter is mandatory only if SSL Authentication is set to Enable.

    Enter the password of the trust store.

    Keystore

    This parameter is mandatory only if SSL Authentication Mode is set to Two-way SSL.

    This parameter specifies the keystore used by the client during SSL two-way authentication. It must match the public key used by the server.

    Keystore Password

    This parameter is mandatory only if SSL Authentication Mode is set to Two-way SSL.

    Enter the password of the keystore.

    Keystore Key Password

    This parameter is mandatory only if SSL Authentication Mode is set to Two-way SSL.

    Enter the password of the keystore key. If this parameter is not specified, the keystore key password is the same as the keystore password.

    The connection configuration of the ArtemisMQ data source is similar to that of ActiveMQ. For details about the configuration example, see Figure 1.

  5. Click Check Connectivity to check the connectivity between ROMA Connect and the data source.
    • If the test result is Data source connected successfully, go to the next step.
    • If the test result is Failed to connect to the data source, check the data source status and connection parameters, and click Recheck until the connection is successful.
  6. Click Create.