Updated on 2024-11-08 GMT+08:00

MySQL CDC Source Table

Function

The MySQL CDC source table, that is, the MySQL streaming source table, reads all historical data in the database first and then smoothly switches data read to the Binlog to ensure data integrity.

Prerequisites

  • MySQL CDC requires MySQL 5.7 or 8.0.x.
  • An enhanced datasource connection has been created for DLI to connect to the MySQL database, so that you can configure security group rules as required.
  • In Flink cross-source development scenarios, there is a risk of password leakage if datasource authentication information is directly configured. You are advised to use the datasource authentication provided by DLI.

    For details about datasource authentication, see Introduction to Datasource Authentication.

  • Binlog is enabled for MySQL, and binlog_row_image is set to FULL.
  • A MySQL user has been created and granted the SELECT, SHOW DATABASES, REPLICATION SLAVE, and REPLICATION CLIENT permissions.

Precautions

  • When creating a Flink OpenSource SQL job, you need to set Flink Version to 1.12 on the Running Parameters tab of the job editing page, select Save Job Log, and set the OBS bucket for saving job logs.
  • Each client that synchronizes database data has a unique ID, that is, the server ID. You are advised to configure a unique server ID for each MySQL CDC job in the same database.
    Main reasons are as follows:
    • The MySQL server maintains the network connection and Binlog location based on the ID. Therefore, if a large number of clients with the same server ID connect to the MySQL server, the CPU usage of the MySQL server may increase sharply, affecting the stability of online services.
    • If multiple jobs share the same server ID, Binlog locations will be disordered, making data read inaccurate. Therefore, you are advised to configure different server IDs for each MySQL CDC job.
  • Watermarks cannot be defined for MySQL CDC source tables. For details about window aggregation, see FAQ.
  • If you connect to a sink source that supports upsert, such as GaussDB(DWS) and MySQL, you need to define the primary key in the statement for creating the sink table. For details, see the printSink table creation statement in Example.
  • When using the MySQL CDM source table, do not manually disable debezium.connect.keep.alive in the source table parameters. Make sure that debezium.connect.keep.alive is set to true (default value).

    If debezium.connect.keep.alive is manually disabled and there is a connection exception between the Binlog thread and the MySQL server, the Binlog thread will not attempt to reconnect automatically. This may result in the inability to properly pull binlog logs from the source.

Syntax

create table mySqlCdcSource (
  attr_name attr_type 
  (',' attr_name attr_type)* 
  (','PRIMARY KEY (attr_name, ...) NOT ENFORCED)
)
with (
  'connector' = 'mysql-cdc',   
  'hostname' = 'mysqlHostname',
  'username' = 'mysqlUsername',
  'password' = 'mysqlPassword',
  'database-name' = 'mysqlDatabaseName',
  'table-name' = 'mysqlTableName'
);

Parameters

Table 1 Parameters

Parameter

Mandatory

Default Value

Data Type

Description

connector

Yes

None

String

Connector to be used. Set this parameter to mysql-cdc.

hostname

Yes

None

String

IP address or hostname of the MySQL database.

username

Yes

None

String

Username of the MySQL database.

password

Yes

None

String

Password of the MySQL database.

database-name

Yes

None

String

Name of the database to connect.

The database name supports regular expressions to read data from multiple databases. For example, flink(.)* indicates all database names starting with flink.

table-name

Yes

None

String

Name of the table to read data from.

The table name supports regular expressions to read data from multiple tables. For example, cdc_order(.)* indicates all table names starting with cdc_order.

port

No

3306

Integer

Port number of the MySQL database.

server-id

No

A random value from 5400 to 6000

String

A numeric ID of the database client, which must be globally unique in the MySQL cluster. You are advised to set a unique ID for each job in the same database.

By default, a random value ranging from 5400 to 6400 is generated.

scan.startup.mode

No

initial

String

Startup mode for consuming data.

  • initial (default): In the first startup, the database scans all historical data and then reads the latest Binlog data.
  • latest-offset: In the first startup, the database reads data directly from the end of the Binlog (the latest Binlog) instead of scanning all historical data. That is, it reads only the latest changes after the connector is started.

server-time-zone

No

None

String

Time zone of the session used by the database.

For example, Asia/Shanghai.

pwd_auth_name

No

None

String

Name of datasource authentication of the password type created on DLI.

If datasource authentication is used, you do not need to set the username and password for jobs.

Example

In this example, MySQL-CDC is used to read data from RDS for MySQL in real time and write the data to the Print result table. The procedure is as follows (MySQL 5.7.32 is used in this example):

  1. Create an enhanced datasource connection in the VPC and subnet where MySQL locates, and bind the connection to the required Flink elastic resource pool. For details, see Enhanced Datasource Connections.
  2. Set MySQL security groups and add inbound rules to allow access from the Flink queue. Test the connectivity using the MySQL address by referring to Testing Address Connectivity. If the connection is successful, the datasource is bound to the queue. Otherwise, the binding fails.
  3. Create a table named cdc_order in database flink of the MySQL database.
    CREATE TABLE `flink`.`cdc_order` (
    	`order_id` VARCHAR(32) NOT NULL,
    	`order_channel` VARCHAR(32) NULL,
    	`order_time` VARCHAR(32) NULL,
    	`pay_amount` DOUBLE  NULL,
    	`real_pay` DOUBLE  NULL,
    	`pay_time` VARCHAR(32) NULL,
    	`user_id` VARCHAR(32) NULL,
    	`user_name` VARCHAR(32) NULL,
    	`area_id` VARCHAR(32) NULL,
    	PRIMARY KEY (`order_id`)
    )	ENGINE = InnoDB
    	DEFAULT CHARACTER SET = utf8mb4
    	COLLATE = utf8mb4_general_ci;
  4. Create a Flink OpenSource SQL job. Enter the following job script and submit the job.
    When you create a job, set Flink Version to 1.12 on the Running Parameters tab. Select Save Job Log, and specify the OBS bucket for saving job logs. Change the values of the parameters in bold as needed in the following script.
    create table mysqlCdcSource(
      order_id string,
      order_channel string,
      order_time string,
      pay_amount double,
      real_pay double,
      pay_time string,
      user_id string,
      user_name string,
      area_id STRING
    ) with (
      'connector' = 'mysql-cdc',
      'hostname' = 'mysqlHostname',
      'username' = 'mysqlUsername',
      'password' = 'mysqlPassword',
      'database-name' = 'mysqlDatabaseName',
      'table-name' = 'mysqlTableName'
    );
    
    create table printSink(
      order_id string,
      order_channel string,
      order_time string,
      pay_amount double,
      real_pay double,
      pay_time string,
      user_id string,
      user_name string,
      area_id STRING,
      primary key(order_id) not enforced
    ) with (
      'connector' = 'print'
    );
    
    insert into printSink select * from mysqlCdcSource;
  5. Insert test data in MySQL.
    insert into cdc_order values
    ('202103241000000001','webShop','2021-03-24 10:00:00','100.00','100.00','2021-03-24 10:02:03','0001','Alice','330106'),
    ('202103241606060001','appShop','2021-03-24 16:06:06','200.00','180.00','2021-03-24 16:10:06','0001','Alice','330106');
    
    delete from cdc_order  where order_channel = 'webShop';
    
    insert into cdc_order values('202103251202020001','miniAppShop','2021-03-25 12:02:02','60.00','60.00','2021-03-25 12:03:00','0002','Bob','330110');
  6. Perform the following operations to view the data result in the taskmanager.out file:
    1. Log in to the DLI console. In the navigation pane, choose Job Management > Flink Jobs.
    2. Click the name of the corresponding Flink job, choose Run Log, click OBS Bucket, and locate the folder of the log you want to view according to the date.
    3. Go to the folder of the date, find the folder whose name contains taskmanager, download the taskmanager.out file, and view result logs.

    The data result is as follows:

    +I(202103241000000001,webShop,2021-03-2410:00:00,100.0,100.0,2021-03-2410:02:03,0001,Alice,330106)
    +I(202103241606060001,appShop,2021-03-2416:06:06,200.0,180.0,2021-03-2416:10:06,0001,Alice,330106)
    -D(202103241000000001,webShop,2021-03-2410:00:00,100.0,100.0,2021-03-2410:02:03,0001,Alice,330106)
    +I(202103251202020001,miniAppShop,2021-03-2512:02:02,60.0,60.0,2021-03-2512:03:00,0002,Bob,330110)

FAQ

Q: How do I perform window aggregation if the MySQL CDC source table does not support definition of watermarks?

A: You can use the non-window aggregation method. That is, convert the time field into a window value, and then use GROUP BY to perform aggregation based on the window value.

For example, you can use the following script to collect statistics on the number of orders per minute (order_time indicates the order time, in the string format):

insert into printSink select DATE_FORMAT(order_time, 'yyyy-MM-dd HH:mm'), count(*) from mysqlCdcSource group by DATE_FORMAT(order_time, 'yyyy-MM-dd HH:mm');