log_min_messages
Parameter description: Specifies which level of messages will be written into server logs. Each level covers all the levels following it. The lower the level is, the fewer messages will be written into the log.
If the values of client_min_messages and log_min_messages are the same, they indicate different levels.
Type: SUSET
Valid values: enumerated values. Valid values are debug, debug5, debug4, debug3, debug2, debug1, info, log, notice, warning, error, fatal, and panic. For details about the parameters, see Table 1.
Default value: warning
enable_alarm
Parameter description: Specifies whether to enable the alarm detection thread to detect the fault scenarios that may occur in the database.
Type: POSTMASTER
Value range: Boolean
- on: Alarm detection thread is enabled.
- off: Alarm detection thread is disabled.
Default value: on