Error netty.exception.LocalTransportException Is Reported During Flink Job Runtime
Symptom
The error message "netty.exception.LocalTransportException" is displayed during Flink job runtime.
Possible Causes
Network jitter or packet loss occurs. The following tasks time out during the netty communications between upstream and downstream operators. During communications, Flink jobs communicate with each other through the socket at the JDK bottom layer, and only the OS bottom-layer interface is invoked for socket read and write. In this way, IO EXCEPTION or LocalTransPortException is thrown after timeout.
Generally, the root cause is network faults, including:
- Network jitter or packet loss
- Insufficient network bandwidth
- Abnormal network between data nodes
In addition, the open source community also provides some scenarios where this error is triggered.
Solution
If the problem does not occur frequently, for example, once half a year or once a year, you do not need to be worried. If the problem occurs frequently, you are advised to check the network and switch logs. Enable automatic restart. For example, set restart-strategy to failure-rate in the flink-conf.xml file.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.