Basic Parameters of a Management Domain
Parameter Name |
Description |
Setting Requirement |
---|---|---|
Parent Object |
Upper-level management domain name |
The system automatically identifies this name. |
Type |
Management domain type |
The system automatically identifies this type. |
Name |
Management domain name |
The value is a string of 1 to 128 characters. |
Manufacturer |
Manufacturer of the device |
The value is a string of 0 to 64 characters.
NOTE:
This parameter needs to be set when the domain is FusionModule500. |
SN |
Serial number of the created management domain |
The value is a string of 0 to 128 characters. |
Location |
Physical location of the created management domain |
The value is a string of 0 to 64 characters. |
Plan Power (kW) |
Total power for the created management domain |
The value is a floating number ranging from 1 to 10,000,000 (three decimal places).
NOTE:
This parameter needs to be set when the domain is Park or Building. |
Description |
Description of the created management domain |
The value is a string of 0 to 512 characters. |
Longitude |
Longitude of the position where the created management domain is located |
Value range: –180 to +180. A maximum of 10 decimal places are allowed. |
Latitude |
Latitude of the position where the created management domain is located |
Value range: –90 to +90. A maximum of 10 decimal places are allowed. |
Parameter Name |
Description |
Setting Requirement |
---|---|---|
Parent Object |
Upper-level management domain name |
The system automatically identifies this name. |
Type |
Management domain type |
The system automatically identifies this type. |
Room Type |
Equipment room type, including DG Plant, High Volt. Distribution Plant, Low Volt. Distribution Room, Power Transformer Plant, UPS & Battery Room, Service Room, and Cooling Plant. |
Select the room type as required. |
Design Type |
Site design type. You can set this parameter to floor planning or background planning. |
Select the site design type as required.
NOTE:
This parameter needs to be set when the domain is Site. |
Name |
Management domain name |
The value is a string of 1 to 128 characters. |
Planned Rack Position |
Planned number of cabinet places in the created management domain. The number of cabinets in the equipment room cannot exceed the planned number of cabinet places. |
The value is an integer ranging from 1 to 2000.
NOTE:
The value of Planned Rack Position can be modified after it is set. The number of cabinets cannot exceed its planned number. Therefore, you should set enough number of planned cabinets to meet requirements in cabinet creation. |
Wire Laying |
Cabling of the created management domain |
Select UpLine or Downline from the down-down list box. |
SN |
Serial number of the created management domain |
The value is a string of 0 to 128 characters. |
Address |
Address of the created management domain |
The value is a string of 0 to 128 characters. |
Department |
Department of the created management domain |
The value is a string of 0 to 128 characters. |
City |
Name of the city where the created management domain is located |
The value is a string of 0 to 128 characters. |
Country |
Name of the country where the created management domain is located |
The value is a string of 0 to 64 characters. |
Level |
Level of the created management domain |
Select Tier 1, Tier 2, Tier 3, Tier 4, A, B, or C from the drop-down list box. |
Description |
Description of the created management domain |
The value is a string of 0 to 512 characters. |
Owner |
Management personnel for the created management domain |
The value is a string of 0 to 64 characters. |
Longitude |
Longitude of the position where the created management domain is located |
Value range: –180 to +180. A maximum of 10 decimal places are allowed. |
Latitude |
Latitude of the position where the created management domain is located |
Value range: –90 to +90. A maximum of 10 decimal places are allowed. |
City Power Supply Mode |
City power supply mode of the created management domain |
Select Dual power supply or Single power supply from the drop-down list box. |
Voltage Type (VAC) |
Voltage system of the created management domain |
Select 110V, 220V, or 380V from the drop-down list. |
UPS Working Mode |
UPS working mode of the created management domain |
Select N, N+X(X=1~N), 2N, or 2(N+1) from the drop-down list box. |
Has Generator |
Whether a generator is installed in the created management domain |
Select Single Generator, Dual Generator, or NULL from the drop-down list box. |
Input Voltage |
Input voltage of the created management domain |
Select 6KV, 10KV, or 35KV from the drop-down list box.
NOTE:
This parameter needs to be set when the domain is Site. |
Output Voltage |
Output voltage of the created management domain |
Select 110V, 220V, 380V, or 400V from the drop-down list box.
NOTE:
This parameter needs to be set when the domain is Site. |
Plan Power (kW) |
Total power supply for the created management domain |
The value is a floating number ranging from 1 to 10,000,000 (three decimal places). |
Frequency |
Mains power frequency of the created management domain |
Select 50Hz or 60Hz from the drop-down list box. |
Cooling Mode |
Refrigerating mode of the created management domain |
Select Water Cooled Direct Expansion, Air Cooled Direct Expansion, Chilled-water refrigeration, Double-cold Source, or Free cooling from the drop-down list. |
Air-Distribution |
Air supply mode of the equipment room |
Select Underfloor Air Distribution, Horizontal Air Distribution, Side displacement Air-distribution, Vertical Overhead Air Distribution, Horizontal overhead Air-distribution, or Fresh air convection from the drop-down list box. |
Plan Refrigerating Capacity (kW) |
Cooling power of the created management domain |
The value is a floating number ranging from 1 to 10,000,000 (three decimal places). |
Parameter |
Description |
Setting Requirement |
---|---|---|
Parent Object |
Upper-level management domain name |
The system automatically identifies this name. |
Type |
Type of the added container |
The system automatically identifies this type. |
Container Type |
Type of the container you can add |
Select Device Container, Cooling Container, Generator Container, Power Container, NOC Container, AIO Container, Container Cluster, or Transformer. |
Name |
Name of the container |
The value is a string of 1 to 128 characters. |
SN |
SN of the added container |
The value is a string of 0 to 128 characters. |
Box Size |
Size of the container |
Select 20-Feet or 40-Feet. |
Location |
Physical location of the added container |
The value is a string of 0 to 64 characters. |
Description |
Description of the added container |
The value is a string of 0 to 512 characters. |
Left Image, Right Image, Back Image |
You can set Left Image, Right Image, and Back Image of a container. |
NOTE:
The container on the view uses the default image. To manually change the background image of the container, contact the technical support to obtain the image. If the background image of the container is not set, Not Uploaded is displayed. After the background image of the container is uploaded, Wait Save is displayed. After you click in the upper area of the current page, Uploaded is displayed. After the background image of the container is set, you can perform the following operations to check the setting in the View page. Method: Click on the right of the position column. In the displayed Upload Image dialog box, click . Select the obtained image on the local PC and click OK. To delete the uploaded background image, click , and then click Clear in the displayed Upload Image dialog box. |
Count |
You can select the number of containers to be combined. |
You can combine two to twenty equipment containers.
NOTE:
This parameter needs to be set when Container Type is Container Cluster. |
Children Name |
You can set the name of a container. |
The value is a string of 1 to 30 characters.
NOTE:
This parameter needs to be set when Container Type is Container Cluster. |
Name |
Description |
Setting Requirement |
---|---|---|
Parent Object |
Management domain name of the smart module |
The system automatically identifies this name. |
Type |
Type of a smart module |
The system automatically identifies this type. |
Name |
Name of the smart module. |
The value is a string of 1 to 128 characters. |
Manufacturer |
Manufacturer of the device |
The value is a string of 0 to 64 characters. |
Direction |
Direction of the device |
The default value is Horizontal. Select Horizontal or Vertical from the drop-down list box. |
Layout |
Layout of the device |
The default value is single-row wide aisle1. Select single-row wide aisle1, single-row wide aisle2, dual-row wide aisle, single-row narrow aisle1, single-row narrow aisle2, or single-row dual aisle from the drop-down list box. |
Half-Size Cabinet |
Number of half-sized cabinets in each row of the smart module |
The default value is 11. Number of half-sized cabinets in each row of the smart module. The value is an integer ranging from 4 to 50. |
Location |
Position of the smart module in the management domain |
The value is a string of 0 to 64 characters. |
Install Mode |
Installation mode of the smart module |
The default value is Floor Installation. Select Floor Installation, Cabinet Installation, Wall Installation, or Ceiling Installation. |
Wire Type |
Cabling mode of the smart module |
The default value is Ascending Line. Select Ascending Line, Down Line, or Floor Line. |
Airflow Type |
Heat dissipation channel of the smart module. |
The default value is Vertical Under-Floor Air-Distribution. Select Vertical Under-Floor Air-Distribution, Horizontal Displacement Air-Distribution, Side Displacement Air-Distribution, Vertical Overhead Air-Distribution, Horizontal Overhead Air-Distribution, or Natural Convection Overhead Air-Distribution. |
Aisle Size |
Width of the aisle in the smart module |
The default value is 1200. The value is an integer ranging from 0 to 65,535. |
Height |
Height of the smart module |
The default value is 2300. Select 2300, 2500, or 2800 from the drop-down list box. |
Aisle Containment Type |
Aisle containment type of a smart module |
The default value is Cold Aisle. Select Hot Aisle or Cold Aisle from the drop-down list box. |