AI Features
enable_hypo_index
Parameter description: Specifies whether the database optimizer considers the created virtual index when executing the EXPLAIN statement. By executing EXPLAIN on a specific query statement, you can evaluate whether the index can improve the execution efficiency of the query statement based on the execution plan provided by the optimizer.
This is a USERSET parameter. Set it based on instructions provided in Table 2.
Value range: Boolean
- on indicates that a virtual index is created during EXPLAIN execution.
- off indicates that no virtual index is created during EXPLAIN execution.
Default value: off
enable_ai_stats
Parameter description: Specifies whether to create or use intelligent statistics.
This is a USERSET parameter. Set it based on instructions provided in Table 2.
Value range: Boolean
Default value: off
multi_stats_type
Parameter description: Specifies the type of statistics to be created when enable_ai_stats is set to on.
This is a USERSET parameter. Set it based on instructions provided in Table 2.
Value range: BAYESNET, MCV, or ALL.
- BAYESNET: Only intelligent statistics are created.
- MCV: Only traditional statistics are created.
- ALL: Both traditional statistics and intelligent statistics are created.
Default value: BAYESNET
ai_stats_cache_limit
Parameter description: Specifies the maximum number of models that can be cached when enable_ai_stats is set to on.
This is a USERSET parameter. Set it based on instructions provided in Table 2.
Value range: an integer ranging from 30 to 1000
Default value: 100
enable_operator_prefer
Parameter description: Specifies whether to enable the operator preference rule. If the estimated costs are similar, the parameterized path is preferred for table join. Note: There are two prerequisites for this parameter to take effect: 1. The parameterized path is generated. 2. The estimated cost of the parameterized path is similar to that of other index scan operators.
This is a USERSET parameter. Set it based on instructions provided in Table 2.
Value range: Boolean
Default value: off
enable_ai_watchdog
Parameter description: Enables or disables the AI watchdog function.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: Boolean
- on: enabled.
- off: disabled.
Default value: on
enable_ai_watchdog_forcible_oom_detection
Parameter description: Forcibly enables or disables OOM detection of the AI watchdog. If this parameter is disabled, the system automatically determines whether to enable OOM detection based on the current database specifications. In automatic determination mode, OOM detection is enabled only when max_process_memory is set to 64 GB or larger.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: Boolean
- on: enabled.
- off: disabled.
Default value: off
enable_ai_watchdog_healing
Parameter description: Enables or disables the self-healing function of the AI watchdog. You are advised not to enable this function because it is easy to cause suspension in high-load scenarios with 16-core CPU or lower specifications.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: Boolean
- on: enabled.
- off: disabled.
Default value: on
ai_watchdog_max_cpu_usage
Parameter description: Specifies the expected upper limit of the database CPU usage. The value is normalized based on the multi-core situation. If this parameter is set to 0, the system does not check the CPU usage.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: a floating-point number ranging from 0 to 1.
Default value: 0.8
ai_watchdog_oom_dynamic_used_threshold
Parameter description: Specifies the expected upper limit of the dynamic memory usage of the database.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: a floating-point number ranging from 0 to 1.
Default value: 0.95
ai_watchdog_oom_growth_confidence
Parameter description: Specifies the confidence level of the OOM detection algorithm.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: a floating-point number ranging from 0.1 to 1.
Default value: 0.95
ai_watchdog_oom_malloc_failures
Parameter description: Specifies the maximum number of consecutive memory allocation failures tolerated. If the number of consecutive memory allocation failures exceeds this value, the OOM detection function may be triggered.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: an integer ranging from 1 to 32000.
Default value: 50
ai_watchdog_oom_other_used_memory_threshold
Parameter description: Specifies the expected upper limit of memory usage of other parts of the database, in MB.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: an integer ranging from 1 to 32000.
Default value: 20480
ai_watchdog_oom_process_threshold
Parameter description: Specifies the expected percentage of the database process usage to the value of max_process_memory. When the threshold is reached, memory leakage determination is triggered. The value can be greater than 1.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: a floating-point number ranging from 0 to 10.
Default value: 1.1
ai_watchdog_oom_shared_threshold
Parameter description: Specifies the expected upper limit of the shared memory usage of the database.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: a floating-point number ranging from 0 to 1.
Default value: 0.4
ai_watchdog_rto_restriction_time
Parameter description: Specifies the RTO threshold of the AI watchdog self-healing function. If the RTO threshold is exceeded, self-healing is not performed. The unit is second.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: an integer ranging from 0 to 36000.
Default value: 600
ai_watchdog_tolerance_times
Parameter description: Specifies the maximum number of consecutive abnormal events that can be tolerated by the AI watchdog before self-healing is started. This parameter can be used to avoid incorrect operations.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: an integer ranging from 0 to 100.
Default value: 4
ai_watchdog_tps_threshold
Parameter description: Specifies the lower limit of the expected TPS usage of the database instance. If the TPS usage is lower than the value of this parameter, the exception determination logic is triggered.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: an integer ranging from 0 to 32000.
Default value: 2
ai_watchdog_wait_time
Parameter description: Adjusts the waiting time, in seconds. To prevent the database from frequently performing self-healing operations, the database waits for a period of time after startup.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: an integer ranging from 0 to 36000.
Default value: 1800
ai_watchdog_warning_retention
Parameter description: Specifies the maximum number of alarm records that the AI watchdog can retain in the dbe_perf.ai_watchdog_detection_warnings view.
This is a SIGHUP parameter. Set it based on instructions provided in Table 2.
Value range: an integer ranging from 0 to 32000.
Default value: 20
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot