System Variable (SYS)
In general, preset system variables are obtained from the public data such as the system time and access code in the system environment and session.
Parameter |
Description |
---|---|
SYS.systemDate |
System date. The value is a character string. The value format is YYYYMMDD, with four digits for the year, two digits for the month, and two digits for the date. If the number of digits is insufficient, use 0 for padding. For example, April 12, 2019 can be expressed as 20190412. |
SYS.systemMonth |
System year and month. The value is a character string. The value format is YYYYMM, with four digits for the year and two digits for the month. If the number of digits is insufficient, use 0 for padding. For example, April 2019 can be expressed as 201904. |
SYS.systemTime |
Current system time. The value is a character string. The value format is HHmmss, with two digits for each of the hour (24-hour format), minute, and second. If the number of digits is insufficient, use 0 for padding. For example, 16:00 can be expressed as 160000. |
SYS.callingNumber |
Customer phone number. When a call is connected to the AICC, this parameter indicates the calling number. When a call is made by the AICC, this parameter indicates the called number. Both the calling number and called number are customer phone numbers. The value is a character string. The number is transferred by an IVR flow. |
SYS.calledNumber |
Access code. The value is a character string. The access code is transferred by an IVR flow, and can be viewed on the web application server (WAS) console of the computer telephony integration (CTI) platform. |
SYS.realCalledNumber |
Access code configured on the Called Party page for the flow, that is, the hotline number dialed by the flow. |
SYS.callId |
Session ID on the ODFS. The value is a character string. The ID is transferred by the IVR flow, that is, IVRREQUEST.call_id. |
SYS.cti_callid |
CTI call ID transferred by the IVR flow, that is, IVRREQUEST.cti_callid on the IVR side. |
SYS.tenantId |
Current tenant ID. The value is a character string. |
SYS.language |
Current customer language. The value is a character string. To support multiple languages, assign a value to this variable. For example, assign en_US for English. |
SYS.timeStamp |
Timestamp, which is a character string. Total number of seconds from 1970-01-01 00:00:00 (GMT) (Beijing time 1970-01-01 08:00:00) to the current time. |
SYS.callMediaType |
Call media type.
|
SYS.currentTime |
Current system time, which is in yyyyMMddHHmmss format. |
SYS.createTime |
Call start time. |
Expressions that contain parameters comply with JavaScript syntax, and the result is of the boolean type. For example, in the Batch Judgment diagram element, you can determine whether the current time is within or beyond the service time using the following expressions.
- Service Hours: (SYS.systemTime > '110000') && (SYS.systemTime < '220000')
- Non-service hours: (SYS.systemTime < '110000') || (SYS.systemTime > '220000')
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.