Deze pagina is nog niet beschikbaar in uw eigen taal. We werken er hard aan om meer taalversies toe te voegen. Bedankt voor uw steun.

On this page

Show all

GAUSS-02301 -- GAUSS-02310

Updated on 2024-03-15 GMT+08:00

GAUSS-02301: "frame starting offset must not be null"

SQLSTATE: 22004

Description: The start offset specified by the window frame clause is NULL.

Solution: Check the SQL statement to ensure that the start offset in the frame clause is not empty.

GAUSS-02302: "frame starting offset must not be negative"

SQLSTATE: 22023

Description: The start offset specified by the window frame clause is negative.

Solution: Check the SQL statement to ensure that the start offset in the frame clause is not negative.

GAUSS-02303: "frame ending offset must not be null"

SQLSTATE: 22004

Description: The ending offset specified by the window frame clause is NULL.

Solution: Check the SQL statement to ensure that the ending offset in the frame clause is not empty.

GAUSS-02304: "frame ending offset must not be negative"

SQLSTATE: 22023

Description: The ending offset specified by the window frame clause is negative.

Solution: Check the SQL statement to ensure that the ending offset in the frame clause is not negative.

GAUSS-02305: "unexpected end of tuplestore"

SQLSTATE: 22000

Description: Failed to obtain data.

Solution: The internal logic of the executor is incorrect. Contact technical support.

GAUSS-02306: "WindowFunc with winref %u assigned to WindowAgg with winref %u"

SQLSTATE: 42804

Description: Plan error. The sequence number of WindowFunc does not match that in WindowAgg.

Solution: Contact technical support.

GAUSS-02307: "aggregate %u needs to have compatible input type and transition type"

SQLSTATE: 42P13

Description: The type of the input parameter or the intermediate data is incompatible with the data type of aggregate functions.

Solution: Modify the data type of the input parameter or intermediate data.

GAUSS-02308: "cannot fetch row before WindowObject's mark position"

SQLSTATE: 22P08

Description: The internal execution logic is faulty.

Solution: Contact technical support.

GAUSS-02309: "cannot move WindowObject's mark position backward"

SQLSTATE: 0A000

Description: The internal execution logic is faulty.

Solution: Contact technical support.

GAUSS-02310: "specified position is out of window: "

SQLSTATE: XX000

Description: The internal execution logic is faulty.

Solution: Contact technical support.

Feedback

Feedback

Feedback

0/500

Selected Content

Submit selected content with the feedback