Deze pagina is nog niet beschikbaar in uw eigen taal. We werken er hard aan om meer taalversies toe te voegen. Bedankt voor uw steun.

On this page

Show all

GAUSS-02041 -- GAUSS-02050

Updated on 2024-03-15 GMT+08:00

GAUSS-02041: "could not fsync file '%s': %m"

SQLSTATE: XX000

Description: Files cannot be synchronized.

Solution: Resolve the problem based on concrete error codes.

GAUSS-02042: "could not read file '%s', read %d of %u: %m"

SQLSTATE: XX000

Description: Internal system error.

Solution: Contact technical support.

GAUSS-02043: "replication slot file '%s' has wrong magic %u instead of %u"

SQLSTATE: XX000

Description: The flag in the replication slot file does not match with that in the current version supported.

Solution: Check whether the replication slot file is maliciously modified or whether the current program version is subject to major version upgrade.

GAUSS-02044: "replication slot file '%s' has unsupported version %u"

SQLSTATE: XX000

Description: The version specified in the replication slot file does not match with that in the current version supported.

Solution: Check whether the replication slot file is maliciously modified or whether the current program version is subject to major version upgrade.

GAUSS-02045: "replication slot file '%s' has corrupted length %u"

SQLSTATE: XX000

Description: The read length in the replication slot file does not meet expectations.

Solution: Check whether the replication slot file is maliciously modified or whether the current program version is subject to major version upgrade.

GAUSS-02046: "replication slot file %s: checksum mismatch, is %u, should be %u"

SQLSTATE: XX000

Description: The CRC recorded in the replication slot file is inconsistent with the file CRC.

Solution: Check whether the replication slot file is maliciously modified.

GAUSS-02047: "too many replication slots active before shutdown"

SQLSTATE: XX000

Description: Too many replication slots are activated before the last database shutdown.

Solution: Check whether the max_replication_slots parameter is set to a small value. If it is, set the parameter to a larger value and restart the database.

GAUSS-02048: "wal receiver could not connect to the primary server,the connection info :%s : %s"

SQLSTATE: XX000

Description: The walreceiver thread fails to connect to the primary server. Determine the reason based on the error message.

Solution:"1. Timeout: Check whether it is due to service overload of the primary server. 2. Connection failure: Check whether the primary server is started. "

GAUSS-02049: "could not receive database system version and protocol version from the primary server: %s"

SQLSTATE: XX000

Description: The standby server sends a version verification message to the primary server. The primary server returns a failure message. Resolve the problem based on the "%s" error message.

Solution:"1. If the network connection times out, adjust the current network environment. If the primary server is overloaded, adjust services. 2. If the primary server is shut down unexpectedly, identify the cause. "

GAUSS-02050: "could not get the local protocal version, make sure the PG_PROTOCOL_VERSION is defined"

SQLSTATE: XX000

Description: The local version information fails to be obtained.

Solution: Ensure that the current memory is sufficient.

Feedback