Restarting a CBH Instance
If your CBH system becomes abnormal, you can try restarting the mapped CBH instance.
- You can restart a CBH instance in the Running status.
- Restarting a CBH instance will interrupt services of the mapped CBH system for about 5 minutes. During this period, the instance status is Restarting.
- The CBH system will be unavailable when the mapped CBH instance is being restarted.
Prerequisites
- You have obtained credentials for logging in to the management console.
- A valid EIP has been bound to the CBH instance.
Procedure
- Log in to the management console.
- Go to the page for viewing CBH instance information by following the steps in Figure 1.
- Locate the row containing the instance you want restart. In the Operation column, choose More > Restart.
- In the displayed dialog box, click OK.
The restart process takes about 5 minutes. During the restart, the CBH instance will be in the Restarting status.
The restart may take a longer time if both the CBH instance version upgrade and capacity expansion are performed.
When the CBH instance status changes to Running, the CBH system is available.
To forcibly restart a CBH instance, select the Forcibly restart check box in the displayed dialog box. Forcibly stopping an instance may cause data loss. Ensure that all data files have been saved before performing this operation. Be sure no operations are performed in the mapped CBH system.
Last Article: Stopping a CBH Instance
Next Article: Binding an EIP to a CBH Instance