ALM-3276800002 Indicates that temperature exceeded the lower pre-alarm limit
Description
SRM/3/TEMPFALLINGALARM: OID [OID] temperature below minor threshold .(EntityPhysicalIndex=[INTEGER1], BaseThresholdEntry_entPhysicalIndex=[INTEGER2], BaseThresholdEntry_hwBaseThresholdType=[INTEGER3], BaseThresholdEntry_hwBaseThresholdIndex=[INTEGER4], BaseTrapSeverity=[INTEGER5], BaseTrapProbableCause=[INTEGER6], BaseTrapEventType=[INTEGER7], EntPhysicalName=[OCTET], BaseThresholdValue=[INTEGER8], BaseThresholdUnit=[INTEGER9], BaseThresholdLowCritical=[INTEGER10], BaseThresholdLowWarning=[INTEGER11])
This alarm was generated when the temperature was lower than the lower threshold.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
3276800002 |
Minor |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
EntityPhysicalIndex |
Entity index. |
BaseThresholdEntry_entPhysicalIndex |
Index of the entity causing this temperature alarm. |
BaseThresholdEntry_hwBaseThresholdType |
Type of the detected entity (The value 1 indicates the temperature sensor of a certain type that is adopted by the S-switch.) |
BaseThresholdEntry_hwBaseThresholdIndex |
Index of the temperature sensor (The value begins from 1.) |
BaseTrapSeverity |
Severity code. |
BaseTrapProbableCause |
Error code. |
BaseTrapEventType |
Code of the event type. |
EntPhysicalName |
Entity name. |
BaseThresholdValue |
Current temperature. |
BaseThresholdUnit |
Unit of the temperature. |
BaseThresholdLowCritical |
Major lower threshold of the temperature. |
BaseThresholdLowWarning |
Lower threshold of the temperature. |
Impact on the System
After the temperature exceeds the lower threshold, the device may fail to work normally. That is, packet loss may occur or even more seriously, the device may be suspended or abnormally reset.
Possible Causes
1. The lower threshold of the temperature was too high.
2. The ambient temperature was too low.
Procedure
- Run the display temperature { all | slot slot-id } command to check whether the ambient temperature is too low.
- If so, increase the ambient temperature by turning up the air-conditioner.
- If not, go to step 2.
- Run the display temperature { all | slot slot-id } command to check whether the set lower threshold of the temperature is too high.
- If so, set the lower threshold of the temperature to a proper value. It is recommended that you run the undo temperature threshold unit unit-id command to restore the lower threshold to the default value.
- If not, the alarm handling ends.