Updated on 2024-01-25 GMT+08:00

ALM-303046663 The PD classes are invalid

Description

POE/4/PDINVALIDCLASS: OID [OID] PD with invalid IEEE class and power denied.(IfIndex=[INTEGER], Interface="[OCTET]")

The system detects that the PD class is invalid.

Attribute

Alarm ID

Alarm Severity

Alarm Type

303046663

Warning

Communication alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

IfIndex

Indicates the interface index.

Interface

Indicates the interface name.

Impact on the System

Services are not affected.

Possible Causes

Cause 1:

The PD may not comply with standards, whereas the switch supports 802.3af and 802.3at. In this case, the PD class cannot be identified by the switch.

Cause 2:

The PD hardware is faulty.

Cause 3:

The PoE chip of the device is faulty.

Procedure

  1. Run the poe legacy enable command on the interface to enable compatibility detection and then check whether the alarm is cleared.

    If so, the alarm handling ends.

    If not, go to step 2.

  2. Replace the PD with a standard PD and then check whether the alarm is cleared.

    If so, the alarm handling ends.

    If not, collect alarm information and configuration information, and then contact technical support personnel.

Related Information

None