ALM-303046662 The PD classes exceed the threshold
Description
POE/4/PDCLASSOVERCURRENT: OID [OID] has detected a classfication overcurrent PD and power denied.(IfIndex=[INTEGER], Interface="[OCTET]")
The system detects that overcurrent occurs during PD classification.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046662 |
Warning |
Communication alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
IfIndex |
Indicates the interface index. |
Interface |
Indicates the interface name. |
Impact on the System
Services are not affected.
Possible Causes
The PD does not comply with standards.
Procedure
- Run the poe high-inrush enable slot slot-id command in the system view to allow high inrush current during power-on and then check whether the alarm is cleared.
If so, the alarm handling ends.
If not, go to step 2.
- Replace the PD with a standard PD and then check whether the alarm is cleared.
If so, the alarm handling ends.
If not, collect alarm information and configuration information, and then contact technical support personnel.
Related Information
None