ALM-3276800320 Fan Is Invalid
Description
ENTITYTRAP/4/FANINVALID:OID [OID] Fan is invalid.(Index=[INT1], EntityPhysicalIndex=[INT2], PhysicalName="[OCTET]", EntityTrapFaultID=[INT3])
The alarm is generated when fans become faulty.
Attribute
Alarm ID |
OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
3276800320 |
1.3.6.1.4.1.2011.5.25.219.2.6.5 |
Warning |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
Resource ID |
Indicates the resource ID of an entity. |
Entity physical index |
Indicates the sub-index of an entity. |
Physical name |
Indicates the name of an entity. |
EntityTrapFaultID |
Indicates the error code of the alarm. |
Impact on the System
The temperature of boards becomes high.
Possible Causes
Fans are faulty. For example, fans stop rotating.
Procedure
- Run the display fan command to check the fan status. Check whether the fan tray is registered and the fan speed is zero.
----End