Updated on 2024-01-25 GMT+08:00

ALM-3276800320 Fan Is Invalid

Description

ENTITYTRAP/4/FANINVALID:OID [OID] Fan is invalid.(Index=[INT1], EntityPhysicalIndex=[INT2], PhysicalName="[OCTET]", EntityTrapFaultID=[INT3])

The alarm is generated when fans become faulty.

Attribute

Alarm ID

OID

Alarm Severity

Alarm Type

3276800320

1.3.6.1.4.1.2011.5.25.219.2.6.5

Warning

Equipment alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

Resource ID

Indicates the resource ID of an entity.

Entity physical index

Indicates the sub-index of an entity.

Physical name

Indicates the name of an entity.

EntityTrapFaultID

Indicates the error code of the alarm.

Impact on the System

The temperature of boards becomes high.

Possible Causes

Fans are faulty. For example, fans stop rotating.

Procedure

  • Run the display fan command to check the fan status. Check whether the fan tray is registered and the fan speed is zero.
    • If the fan tray is not registered, remove and install the fan tray.
    • If the fan speed is zero, replace the fan.

      If the fault persists, contact technical support personnel.

----End