ALM-135462943 hwPowerRemove
Description
The power module was removed. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], EntityOperStatus=[EntityOperStatus], Reason=[ReasonDsp])
A power module was removed.
Attribute
Alarm ID |
OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
135462943 |
1.3.6.1.4.1.2011.5.25.219.2.5.1 |
Critical |
Equipment alarm |
Parameters
Name | Meaning |
---|---|
EntPhysicalIndex |
Indicates the index of an entity. |
EntPhysicalName |
Indicates the name of an entity. |
EntityTrapFaultID |
Indicates the error code. |
EntityOperStatus |
Indicates the Status. |
ReasonDsp |
ndicates a possible cause. |
Impact on the System
The power module is removed, which may cause insufficient power supply. If the power supply is insufficient, the board may be powered off. This affects services. This fault needs to be rectified.
Procedure
- Check whether the power module is installed.
- If so, check whether the power module is installed correctly.
- If the power module is installed correctly but the fault persists, replace the power module.
- If the fault persists after the power module is replaced, collect traps, logs, and configurations, and contact technical support personnel.