Message 513 Is Reported When Devices Are Connected to the IoT Platform
After being powered on, devices initiate a TUP registration flow to the IoT platform. TUP is a Huawei proprietary protocol over CoAP. TUP is similar to LWM2M. HiSilicon chipsets set that the TUP registration cannot exceed 4s. If the TUP registration is not completed within 4 seconds, a 513 message is reported.
When a 513 message is reported, perform the following operations:
- When a 513 message is reported due to poor network performance, contact the NB-IoT network carrier to check the network status.
- When service data is sent by running AT+NMGS, registration is triggered. If the t/d resources (receiving and sending service data resources) are not received within 4 seconds, an error is returned, but the registration is continued based on the CoAP-layer retransmission. If subscription to the t/d resources is not received after 160 seconds, the IoT platform determines that the registration fails. The 160-second duration is sufficient for device registration. If an error message is returned after 4 seconds, only the data of the first packet is discarded. You are advised to restart the device and run AT+NMGS to trigger the registration.
You can run AT+NMSTATUS? to query registration status. If +NMSTATUS:MO_DATA_ENABLED is returned, the registration is successful.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot