ALM-12048 Network Write Packet Error Rate Exceeds the Threshold
Description
The system checks the network write packet error rate every 30 seconds and compares the actual packet error rate with the threshold (the default threshold is 0.5%). This alarm is generated when the system detects that the network write packet error rate exceeds the threshold for several times (5 times by default) consecutively.
To change the threshold, choose O&M > Alarm > Thresholds > Name of the desired cluster > Host > Network Writing > Write Packet Error Rate.
When the Trigger Count is 1, this alarm is cleared when the network write packet error rate is less than or equal to the threshold. When the Trigger Count is greater than 1, this alarm is cleared when the value of the network write packet error rate is less than or equal to 90% of the threshold.
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
12048 |
Major |
Yes |
Parameters
Name |
Meaning |
---|---|
Source |
Specifies the cluster or system for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
NetworkCardName |
Specifies the network port for which the alarm is generated. |
Trigger Condition |
Specifies the threshold triggering the alarm. If the current indicator value exceeds this threshold, the alarm is generated. |
Impact on the System
The communication interrupts intermittently and services time out.
Possible Causes
- The alarm threshold is set improperly.
- The cluster network environment is of poor quality.
Procedure
Check whether the threshold is set properly.
- On the FusionInsight Manager, choose O&M > Alarm > Thresholds > Name of the desired cluster > Host > Network Writing > Write Packet Error Rate and check whether the alarm threshold is set properly. (By default, 0.5% is a proper value. However, users can configure the value as required.)
- Based on actual usage condition, choose O&M > Alarm > Thresholds > Name of the desired cluster > Host > Network Writing > Write Packet Error Rate and click Modify in the Operation column to modify the alarm threshold.
For details, see Figure 1.
- Wait for 5 minutes, and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 4.
Check whether the network is normal.
- Contact the system administrator to check whether the network is abnormal.
- Wait for 5 minutes, and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 6.
Collect fault information.
- On the FusionInsight Manager home page of the active cluster, choose O&M > Log > Download.
- Select OMS from the Service and click OK.
- Set Host to the node for which the alarm is generated and the active OMS node.
- Click in the upper right corner, and set Start Date and End Date for log collection to 30 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact the O&M personnel and send the collected log information.
Alarm Clearing
After the fault is rectified, the system automatically clears this alarm.
Related Information
None