Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ V300 AR Alarms/ ALM-3276800301 The evpn connection has entered the down state
Updated on 2024-01-25 GMT+08:00

ALM-3276800301 The evpn connection has entered the down state

Description

CONN/2/CONN_STATUS_DOWN:OID [OID] The connection has entered the down state. (ConnectionID = [integer1], SrcSiteID = [integer2], SrcTNPID = [integer3], DestSiteID = [integer4], DestTNPID = [integer5])

The iMaster NCE-Campus EVPN link is unavailable.

Attribute

Alarm ID

OID

Alarm Severity

Alarm Type

3276800301

1.3.6.1.4.1.2011.5.25.241.6.3.2

Major

Communication alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

integer1

Indicates the link index.

integer2

Indicates the source site ID.

integer3

Indicates the source TNP ID.

integer4

Indicates the destination site ID.

integer5

Indicates the destination TNP ID.

Impact on the System

The system will not be affected.

Possible Causes

Cause 1:

No keepalive packet was received from the remote device within the configured detection period.

Cause 2:

The protocol status of a physical interface changed.

Cause 3:

The BGP connection between the local and remote sites was interrupted.

Procedure

  1. Check whether the interfaces bound to the TNPs can ping each other successfully.

    • If so, go to 3.
    • If not, go to 2.

  2. Check whether the intermediate transmission network is faulty.
  3. Collect log and configuration information, and contact technical support.

Related Information

None