ALM-3276800300 The session resources were overloaded
Description
FWDTRAP/2/SESSIONRESLACK:OID [OID] The device session resources were overloaded.(Usage = [INTEGER]%)
The number of forwarding flow tables on the device reaches or exceeds 90% or 100% of the maximum number, an alarm is generated.

If the number of forwarding flow tables changes too rapidly within a short period of time, multiple alarms may be generated. As a result, the system records these alarms, affecting normal services on the device. To prevent the device from recording a large number of alarms, the system suppresses the alarms by setting the interval at which alarms are sent to longer than 30 minutes. That is, the system records an alarm at least 30 minutes after the last alarm was cleared.
Attribute
Alarm ID |
OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
3276800300 |
1.3.6.1.4.1.2011.5.25.227.2.1.36 |
Major |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
[OID] |
Indicates the MIB object ID of the alarm. |
Usage |
The proportion that the number of forwarding flow tables on the device accounts for of the maximum number. |
Impact on the System
Services are affected.
Possible Causes
The number of forwarding flow tables on the device reaches or exceeds 90% or 100% of the maximum number.
Procedure
Check service configurations and contact technical support personnel.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot