GAUSS-04927: "old version XLog must be shutdown checkpoint."
SQLSTATE: None
Description: In the upgrade, the cluster is not stopped in smart mode (by using gs_om -t stop).
Solution: Roll back the upgrade, stop the cluster in smart mode, restart it, and then perform the upgrade again.
GAUSS-04928: "old version XLog should not be read."
SQLSTATE: None
Description: In a system using 64-bit transaction IDs, users cannot access Xlogs from a system using 32-bit transaction IDs.
Solution: Internal system error. Contact technical support.
GAUSS-04929: "Can't freeze this heap page and can't fit xid into page."
SQLSTATE: XX000
Description: The heap page cannot be frozen. The xid cannot be inserted into the heap page.
Solution: Execute the transaction again after it is rolled back.
GAUSS-04930: "Can't fit xid into page."
SQLSTATE: XX000
Description: The xid cannot be inserted into the heap page.
Solution: Execute the transaction again after it is rolled back.