ALM-45012 HSFabric GC Duration Exceeds the Threshold
Alarm Description
The system checks the garbage collection (GC) duration of the HSFabric process every 60 seconds. This alarm is generated when the GC duration of the HSFabric process exceeds the threshold (12,000 ms by default) for three consecutive times.
This alarm is automatically cleared when the system detects that the GC duration is less than the threshold.
Alarm Attributes
| Alarm ID | Alarm Severity | Alarm Type | Service Type | Auto Cleared |
|---|---|---|---|---|
| 45012 | Major | Quality of service | HetuEngine | No |
Alarm Parameters
| Type | Parameter | Description |
|---|---|---|
| Location Information | Source | Specifies the cluster for which the alarm was generated. |
| ServiceName | Specifies the service for which the alarm was generated. | |
| RoleName | Specifies the role for which the alarm was generated. | |
| HostName | Specifies the host for which the alarm was generated. | |
| Additional Information | Trigger Condition | Specifies the alarm triggering condition. |
Impact on the System
HSFabric may respond slowly and the access to the HSFabric may be interrupted.
Possible Causes
The heap memory of the HSFabric process is overused or inappropriately allocated, causing frequent occurrence of the GC process.
Handling Procedure
Check the GC duration of the HSFabric process.
- Log in to FusionInsight Manager, choose O&M > Alarm > Alarms > ALM-45012 HSFabric GC Duration Exceeds the Threshold. In the Location field of the alarm details, check the instance host name for which the alarm is generated.
- Choose Cluster > Services > HetuEngine > Instances and click the instance host name for which the alarm is generated. Click the drop-down list in the upper right corner of the chart area, choose Customize > GC > GC Duration of the HSFabric Process, and click OK.
- Check whether the GC duration of the HSFabric process collected every minute exceeds the threshold (12,000 ms by default).
- Choose Cluster > Services > HetuEngine > Instances > HSFabric > Instance Configurations > All Configurations, and select HSFabric > Tuning. Set -Xmx in the GC_OPTS parameter to a larger value based on site requirements and save the configuration.
If this alarm is generated, the heap memory configured for HSFabric cannot meet the heap memory required by the HSFabric process. You are advised to change the value of -Xmx in GC_OPTS to the twice that of the heap memory used by HSFabric. You can change the value based on the actual service scenario. For details about how to check the HSFabric heap memory usage, see Step 2.
- Restart the affected services or instances and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to Step 6.
During the restart of the service or instance, HSFabric may fail to be accessed.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select HetuEngine for the target cluster.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Send the collected fault logs to O&M engineers for help.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None