ALM-45427 ClickHouse Service Capacity Quota Usage in ZooKeeper Exceeds the Threshold
Description
The alarm module checks the quota usage of the ClickHouse service in the ZooKeeper every 60 seconds. This alarm is generated when the alarm module detects that the usage exceeds the threshold (90%).
This alarm is cleared when the system detects that the usage is lower than the threshold and the alarm is cleared.
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
45427 |
Major (default) |
Yes |
Parameters
Name |
Meaning |
---|---|
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
Impact on the System
After the ZooKeeper quantity quota of the ClickHouse service exceeds the threshold, you cannot perform cluster operations on the ClickHouse service on FusionInsight Manager. As a result, the ClickHouse service cannot be used.
Possible Causes
When table data is created, inserted, or deleted, the ClickHouse creates znodes on ZooKeeper nodes. As the service volume increases, the capacity of znodes may exceed the configured threshold.
Procedure
Check the znode capacity of the ClickHouse in the ZooKeeper.
- Log in to the host where the ZooKeeper client is located and log in to the ZooKeeper client.
Switch to the client installation directory.
Example: cd /opt/client
Run the following command to configure environment variables:
source bigdata_env
Run the following command to authenticate the user (skip this step in common mode):
kinit Component service user
Run the following command to log in to the client tool:
zkCli.sh -server service IP address of the node where the ZooKeeper role instance locates:client port
- Run the following command to check the quota used by ClickHouse on ZooKeeper and check whether the ratio of the bytes value of Output stat to the bytes value of Output quota in the command output is greater than 0.9.
listquota /clickhouse
absolute path is /zookeeper/quota/clickhouse Output quota for /clickhouse count=200000,bytes=1000000000 Output stat for /clickhouse count=2667,bytes=60063
- On FusionInsight Manager, choose Cluster > Services > ClickHouse > Configurations > All Configurations, search for the clickhouse.zookeeper.quota.size parameter, and change the value of this parameter to twice the bytes value of Output stat in 2.
- Restart the ClickHouse instance for which the alarm is generated, and check whether the alarm is cleared 5 minutes later.
Collect the fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select ClickHouse for the target cluster.
- Click in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearing
This alarm is automatically cleared after the fault is rectified.
Related Information
None