Archiving
archive_timeout
Parameter description: Specifies the archiving period.
This is a SIGHUP parameter. Set it based on instructions provided in Table 1.
- The server is forced to switch to a new WAL segment file when the period specified by this parameter has elapsed since the last file switch.
- Archived files that are closed early due to a forced switch are still of the same length as full files. Therefore, a very short archive_timeout will bloat the archive storage. You are advised to set archive_timeout to 60s.
Value range: an integer ranging from 0 to 1073741823. The unit is s. 0 indicates that archiving timeout is disabled.
Default value: 0
archive_interval
Parameter description: Specifies the archiving interval.
This is a SIGHUP parameter. Set it based on instructions provided in Table 1.
- Log files are forcibly archived when the period specified by this parameter has elapsed.
- Archiving involves I/O operations. Therefore, frequent archiving is not allowed. In addition, the RPO cannot be set to a large value; otherwise, the PITR will be affected. You are advised to use the default value.
Value range: an integer ranging from 1 to 1000. The unit is second.
Default value: 1
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.