ALM-45292 PolicySync GC Duration Exceeds the Threshold
Alarm Description
The system checks the GC duration of the PolicySync process every 60 seconds. This alarm is generated when the GC duration of the PolicySync process exceeds the threshold for five consecutive times. This alarm is cleared when the GC duration is less than the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
45292 |
Critical (default threshold: 20000ms) Major (default threshold: 12000ms) |
Yes |
Alarm Parameters
Parameter |
Description |
---|---|
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
Trigger Condition |
Specifies the threshold for triggering the alarm. |
Impact on the System
PolicySync responds slowly.
Possible Causes
The heap memory of the PolicySync process is overused or inappropriately allocated, causing frequent occurrence of the GC process.
Handling Procedure
Check the GC duration.
- Log in to FusionInsight Manager and choose O&M > Alarm > Alarms > ALM-45292 PolicySync GC Duration Exceeds the Threshold. Check the location information of the alarm and view the host name of the instance for which the alarm is generated.
- On FusionInsight Manager, choose Cluster > Services > Ranger > Instance. Select the role corresponding to the host name of the instance for which the alarm is generated and click the drop-down list in the upper right corner of the chart area. Choose Customize > GC > PolicySync GC Duration. Click OK.
Figure 1 PolicySync GC Duration
- Check whether the GC duration of the PolicySync process collected every minute exceeds the threshold (12 seconds by default).
- On FusionInsight Manager, choose Cluster > Services > Ranger > Instance > PolicySync. Click Instance Configuration and then All Configurations, and choose PolicySync > System. Set -Xmx in the GC_OPTS parameter to a larger value based on site requirements and save the configuration.
If this alarm is generated, the heap memory configured for PolicySync cannot meet the heap memory required by the PolicySync process. You are advised to change the value of -Xmx in GC_OPTS to twice that of the heap memory used by PolicySync. You can change the value based on the actual service scenario. Refer to 2 to view the PolicySync heap memory usage.
- Restart the affected services or instances and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 6.
When the service is rebooted, it becomes unavailable and can disrupt business operations. When the instance is rebooted, it cannot be used and any tasks running on the current instance node will fail.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select Ranger for the target cluster.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.