Connection Lines Between Diagram Elements
The connection line indicates the execution sequence of a flow with its arrow direction.
Appearance
Parameter Description
- Branch Condition: branch condition corresponding to the current flow connection line.
Except the preset timeout or unmatched condition, other conditions are the branch conditions configured by the diagram element in the previous step.
The following table describes the preset branches.
Table 1 Preset branches Name
Description
Usage Method
timeout1
First timeout
This branch condition is triggered when a third party system (for example, the IVR) determines that a timeout occurs in receiving the customer feedback and sends a message to the OIAP, indicating that the value of input is timeout.
This branch is generally used on the connection line between the Semantic Recognition diagram element to the subsequent node, indicating that semantic recognition times out before a response is received from the customer.
timeout2
Second timeout
During a call, timeout2 is triggered when timeout1 occurs for the second time.
During script flow design, a flow retry is required when the first timeout occurs. If the second timeout occurs, the current step is skipped and the subsequent steps are performed.
nomatch1
First recognition failure
nomatch1 is triggered in either of the following scenarios:
- The Semantic Recognition diagram element does not match a result (that is, the diagram element returns the command word of an unknown intention).
- A third-party system (for example, the IVR) returns a message in which the value of input is nomatch.
In this scenario, the ASR system fails to recognize the intention and sends a failure response to the IVR.
nomatch2
Second recognition failure
During a call, nomatch2 is triggered when nomatch1 occurs for the second time.
error3
Third error
If the trigger condition corresponding to timeout1 and nomatch1 occur for the third time during a call, error3 is triggered.
If the number of error times does not need to be accumulated, use the Error Count Clearance diagram element to clear the number of error times before using this condition.
SYSERROR_INTERFACE
Business interface invoking failure
This branch condition is triggered if an error occurs when the Business Interface Invocation diagram element is used to invoke a third-party interface.
This branch is generally used on the connection line between the Business Interface Invocation diagram element and subsequent node.
SYSERROR_INNER
ODFS internal error
This branch condition is triggered when other unknown errors occur in the ODFS.
slientInsertReply
Direct reply by silent agents
This branch condition can be used only when the Semantic Recognition diagram element of the silent agent system is configured. By using this diagram element, agents can directly answer the call and continue to execute other expected business flows.
- Description: details of the current branch.
Using Connection Lines
Each diagram element in a flow must be connected, except the Call Ending diagram element in special scenarios.