ALM-45736 Guardian Service Unavailable
Description
The alarm module checks the Guardian service status every 60 seconds. This alarm is generated if Guardian is unavailable.
This alarm is cleared after Guardian recovers.
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
45275 |
Critical |
Yes |
Parameters
Name |
Meaning |
---|---|
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
Impact on the System
Guardian cannot work properly.
Possible Causes
- The Ranger or HDFS service on which Guardian depends is abnormal.
- The TokenServer role instance is abnormal.
Procedure
Check the Ranger and HDFS service status.
- On FusionInsight Manager, choose O&M > Alarm > Alarms. On the displayed page, check whether ALM-45275 Ranger Service Unavailable or ALM-14000 HDFS Service Unavailable is reported.
- Handle the alarm by referring to section "ALM-45275 Ranger Service Unavailable" or "ALM-14000 HDFS Service Unavailable".
After the alarm is cleared, wait a few minutes and check whether the alarm GuardianService Unavailable is cleared.
- If yes, no further action is required.
- If no, go to 3.
Check all TokenServer instances.
- Log in to the node where the TokenServer instance is located as user omm and run the ps -ef|grep "ranger-obs-service" command to check whether the TokenServer process exists on the node.
- In the alarm list, check whether the alarm "Guardian Service Unavailable" is cleared.
- If yes, no further action is required.
- If no, go to 5.
Collect the fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select Guardian for the target cluster.
- Click in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearing
This alarm is automatically cleared after the fault is rectified.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.