ALM-303046659 The temperature is abnormal 140545
Description
ENTITYTRAP/1/ENTITYBRDTEMPALARM: OID [OID] Temperature rise over or fall below the warning alarm threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdValue=[INTEGER], EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])
The temperature of the board falls below the lower threshold.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046659 |
Critical |
environmentalAlarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
Index |
Indicates the index. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
PhysicalName |
Indicates the name of the physical entity. |
EntityThresholdType |
Indicates the threshold type of the physical entity. |
EntityThresholdValue |
Indicates the threshold value of the physical entity. |
EntityThresholdCurrent |
Indicates the current value of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
Impact on the System
Services on the board may be affected if the temperature becomes too low.
Possible Causes
The ambient temperature is too low.
Procedure
- Measure the ambient temperature. If the ambient temperature is too low, use air conditioners or heaters to increase the temperature.
- If the ambient temperature is normal, the lower threshold of the temperature may be too high. Run the temperature threshold slot slotid lower-limit lower upper-limit upper command to decrease the lower threshold of the temperature.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot