Help Center> MapReduce Service> User Guide> Alarm Reference (Applicable to MRS 3.x)> ALM-17011 Abnormal Connection Between Oozie and Yarn
Updated on 2023-10-10 GMT+08:00

ALM-17011 Abnormal Connection Between Oozie and Yarn

Alarm Description

Oozie depends on Yarn. After a task is submitted, the system checks Yarn connectivity. This alarm is generated when the service fails the check for 5 consecutive times.

This alarm is cleared when the connection between Oozie and Yarn becomes normal.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

17011

Minor

Yes

Alarm Parameters

Parameter

Description

Source

Specifies the cluster for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Trigger Condition

Specifies the threshold for triggering the alarm.

Impact on the System

The Oozie service is abnormal and tasks cannot be submitted to Yarn.

Possible Causes

  • The Yarn service is abnormal.
  • The connection between Oozie and Yarn is abnormal.

Handling Procedure

Check the YARN service status.

  1. In the service list on FusionInsight Manager, check whether Running Status of Yarn is Normal.

    • If yes, go to 5.
    • If no, go to 2.

  2. In the alarm list, check whether ALM-18000 YARN Service Unavailable is generated.

    • If yes, go to 3.
    • If no, go to 5.

  3. Rectify the fault by performing the operations provided for ALM-18000 Yarn Service Unavailable.
  4. Wait for several minutes and check whether the alarm Abnormal Connection Between Oozie and Yarn is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

Check the connectivity between Oozie and Yarn.

  1. Log in to FusionInsight Manager, choose O&M > Log > Online Search, select the Oozie service, and search for the keyword [Oozie Alarm Enhancement][Yarn] in the log. View the cause in the log, and rectify the fault. In the alarm list, check whether the alarm Abnormal Connection Between Oozie and Yarn is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Select Oozie for Service and click OK.
  3. Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact O&M personnel and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None.