ALM-50205 BE CPU Usage Exceeds the Threshold
Alarm Description
The system checks the CPU usage of the BE instance every 30 seconds. This alarm is generated when the CPU usage exceeds the threshold for multiple consecutive times (3 by default).
This alarm is cleared when Trigger Count is 1 and the CPU usage is less than or equal to the threshold. This alarm is cleared when Trigger Count is greater than 1 and the CPU usage is less than or equal to 80% of the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
50205 |
Critical (default threshold: 95%) Major (default threshold: 90%) |
Quality of service |
Doris |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster or system for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
|
RoleName |
Specifies the role for which the alarm is generated. |
|
HostName |
Specifies the host for which the alarm is generated. |
|
Additional Information |
Detail |
Specifies the alarm triggering condition. |
Impact on the System
Processes respond slowly or do not work.
Possible Causes
The alarm threshold or alarm trigger count is improperly configured.
Handling Procedure
Check whether the alarm threshold or alarm trigger count is properly configured.
- Log in to FusionInsight Manager, choose O&M > Alarm > Thresholds, click the name of the desired cluster, and choose Doris > CPU and Memory > CPU Usage of BE (BE).
- Click the edit button next to Trigger Count, change the number based on site requirements, and click OK.
Trigger Count specifies how many times the threshold can be hit before an alarm is generated.
- Click Modify in the Operation column, change the alarm threshold based on site requirements, and click OK.
- Wait 2 minutes and check whether the alarm is automatically cleared.
- If yes, no further action is required.
- If no, go to 5.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, select Doris for the target cluster, and click OK.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot