Help Center/ MapReduce Service/ User Guide (Ankara Region)/ Alarm Reference/ ALM-50203 FE Memory Usage Exceeds the Threshold
Updated on 2024-11-29 GMT+08:00

ALM-50203 FE Memory Usage Exceeds the Threshold

Alarm Description

The system checks the memory usage of the FE instance every 30 seconds. This alarm is generated when the memory usage exceeds the threshold for multiple consecutive times (3 by default).

This alarm is cleared when Trigger Count is 1 and the memory usage is less than or equal to the threshold. This alarm is cleared when Trigger Count is greater than 1 and the memory usage is less than or equal to 80% of the threshold.

Alarm Attributes

Alarm ID

Alarm Severity

Alarm Type

Service Type

Auto Cleared

50203

Critical (default threshold: 90%)

Major (default threshold: 85%)

Quality of service

Doris

Yes

Alarm Parameters

Type

Parameter

Description

Location Information

Source

Specifies the cluster or system for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Additional Information

Detail

Specifies the alarm triggering condition.

Impact on the System

Processes respond slowly or do not work.

Possible Causes

  • The alarm threshold or alarm trigger count is improperly configured.

Handling Procedure

Check whether the alarm threshold or alarm trigger count is properly configured.

  1. Log in to FusionInsight Manager, choose O&M > Alarm > Thresholds, select the name of the desired cluster, and choose Doris > CPU and Memory > Memory Usage of FE (FE).
  2. Click the edit button next to Trigger Count, change the number based on site requirements, and click OK.

    Trigger Count specifies how many times the threshold can be hit before an alarm is generated.

  3. Click Modify in the Operation column, change the alarm threshold based on site requirements, and click OK.
  4. Wait 2 minutes and check whether the alarm is automatically cleared.

    • If yes, no further action is required.
    • If no, go to 5.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, select Doris for the target cluster, and click OK.
  3. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact O&M engineers and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None.