Help Center/ GeminiDB/ GeminiDB Redis API/ Best Practices/ Suggestions on Alarm Rules of GeminiDB Redis Instance Metrics
Updated on 2025-07-02 GMT+08:00

Suggestions on Alarm Rules of GeminiDB Redis Instance Metrics

After setting alarm rules on the Cloud Eye console, for example, specifying monitored objects and notification policies, you can stay ahead of your instance status. For details, see Configuring Alarm Rules.

This section describes recommended alarm rules of GeminiDB Redis instances.

Table 1 Suggestions on alarm rules of GeminiDB Redis instance metrics

Metric ID

Metric Name

Dimension

Threshold (Raw Value) in Best Practices

Alarm Severity in Best Practices

Alarm Handling Suggestion

redis688_qps_send_total

Total Traffic Sent by the Instance

Instance

≥ 875,000,000 bytes/s for 3 consecutive periods

Major

Comply with Development and O&M Rules.

redis689_qps_receive_total

Total Traffic Received by the Instance

Instance

≥ 875,000,000 bytes/s for 3 consecutive periods

Major

Comply with Development and O&M Rules.

redis803_cluster_all_avg_usec

Average Latency

Instance

≥ 50,000 μs for 5 consecutive periods

Major

  • Check whether the instance has performance bottlenecks in CPU, memory, or connections. If yes, resolve the bottlenecks based on the related suggestions.
  • If service optimization cannot be performed, increase the instance specifications or use specifications with better disk performance. For details, see Changing vCPUs and Memory and Adding Instance Nodes.

redis804_cluster_all_p99_usec

P99 Latency

Instance

≥ 150,000 μs for 5 consecutive periods

Major

  • Check whether the instance has performance bottlenecks in CPU, memory, or connections. If yes, resolve the bottlenecks based on the related suggestions.
  • If service optimization cannot be performed, increase the instance specifications or use specifications with better disk performance. For details, see Changing vCPUs and Memory and Adding Instance Nodes.

redis816_cluster_disk_usage

Storage Usage

Instance

≥ 80% for 3 consecutive periods

Major

Scale up the storage space. For details, see Manually Scaling Up Storage Space.

nosql001_cpu_usage

CPU Usage

Node

≥ 85% for 3 consecutive periods

Major

Upgrade instance specifications or add nodes to reduce the CPU load. For details, see Changing vCPUs and Memory and Adding Instance Nodes.

nosql002_mem_usage

Memory Usage

Node

≥ 85% for 3 consecutive periods

Major

Upgrade memory specifications. For details, see Changing vCPUs and Memory.

redis669_connection_usage

Connection Usage

Node

≥ 80% for 3 consecutive periods

Major

Comply with Development and O&M Rules.

gemini004_bytes_in

Network Input Throughput

Node

≥ 87,500,000 bytes/s for 3 consecutive periods

Major

Comply with Development and O&M Rules.

gemini003_bytes_out

Network Output Throughput

Node

≥ 87,500,000 bytes/s for 3 consecutive periods

Major

Comply with Development and O&M Rules.