Limitations
The IoT platform has the following technical specifications. If the service cannot meet your service requirements, please contact our salespersons.
Device Access
Object |
Description |
Limit |
---|---|---|
Device quantity |
Maximum number of devices for a single account |
No limit |
Number of devices that can be connected to the IoT platform using the Developer Center during commissioning phase. |
20 |
|
Maximum number of sub devices that can be added to a gateway |
1000 |
|
Connection and request |
Maximum number of connections supported by a single MQTT device |
1 |
Maximum number of MQTT requests per second for a single connection |
300 |
|
Maximum throughput (bandwidth) of a single MQTT connection per second, including directly connected devices and gateways |
3 KB/s |
|
Maximum length of a single message reported by an MQTT device |
1 MB |
|
Maximum length of a single message reported by an LWM2M/CoAP device |
1 MB |
Device Management
Object |
Description |
Limit |
---|---|---|
Application |
Maximum number of applications that can be created for a single account |
10 |
Maximum number of devices that can be registered for a single application |
No limit |
|
Product model (profile) |
Maximum number of product models that can be created for a single application |
20 |
Maximum size of the product model package |
4 MB |
|
Batch device registration |
Maximum number of devices that can be batch registered at a time |
30,000 |
Historical device data |
Maximum storage duration of historical device data (days) If a longer data storage duration is required, use the Object Storage Service. |
7 |
Rule |
Maximum number of rules that can be created for a single application |
50 |
Device configuration update file |
Maximum size of the configuration file for a device configuration update (only in JSON format) |
200 KB |
Batch command delivery |
Maximum number of devices that a command can be batch delivered to |
30,000 |
Software/Firmware upgrade |
N/A |
Only LWM2M devices are supported. |
Number of devices for software/firmware upgrade |
Maximum number of devices for which the software/firmware can be upgraded at a time |
30,000 |
Firmware upgrade package |
Maximum size of the firmware upgrade package |
200 MB |
Software upgrade package |
Maximum size of the software upgrade package |
200 MB |
Group |
Maximum number of groups that can be created for a single application |
10 |
Maximum number of levels in a group |
10 |
|
Maximum number of groups that a device can be added to |
1 |
|
Tag |
Maximum number of device tags that can be created for a single application |
2000 |
Device log |
N/A |
Only devices based on Huawei NB-IoT chipsets and LWM2M are supported. |
Management Portal
Object |
Description |
Limit (for the IoT Advanced) |
---|---|---|
Dashboard |
Maximum storage duration of report statistics |
180 days |
Audit log |
Maximum storage duration of logs on the management portal |
90 days |
Northbound API
Object |
Description |
Limit (for the IoT Advanced) |
---|---|---|
Application |
Maximum number of times that an application can call APIs per second |
100 |
Maximum number of messages pushed to an NA per second |
Lower than 10 TPS (recommended). If the rate is higher than 10 TPS, use data forwarding rules. |
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot