Compute
Elastic Cloud Server
Huawei Cloud Flexus
Bare Metal Server
Auto Scaling
Image Management Service
Dedicated Host
FunctionGraph
Cloud Phone Host
Huawei Cloud EulerOS
Networking
Virtual Private Cloud
Elastic IP
Elastic Load Balance
NAT Gateway
Direct Connect
Virtual Private Network
VPC Endpoint
Cloud Connect
Enterprise Router
Enterprise Switch
Global Accelerator
Management & Governance
Cloud Eye
Identity and Access Management
Cloud Trace Service
Resource Formation Service
Tag Management Service
Log Tank Service
Config
OneAccess
Resource Access Manager
Simple Message Notification
Application Performance Management
Application Operations Management
Organizations
Optimization Advisor
IAM Identity Center
Cloud Operations Center
Resource Governance Center
Migration
Server Migration Service
Object Storage Migration Service
Cloud Data Migration
Migration Center
Cloud Ecosystem
KooGallery
Partner Center
User Support
My Account
Billing Center
Cost Center
Resource Center
Enterprise Management
Service Tickets
HUAWEI CLOUD (International) FAQs
ICP Filing
Support Plans
My Credentials
Customer Operation Capabilities
Partner Support Plans
Professional Services
Analytics
MapReduce Service
Data Lake Insight
CloudTable Service
Cloud Search Service
Data Lake Visualization
Data Ingestion Service
GaussDB(DWS)
DataArts Studio
Data Lake Factory
DataArts Lake Formation
IoT
IoT Device Access
Others
Product Pricing Details
System Permissions
Console Quick Start
Common FAQs
Instructions for Associating with a HUAWEI CLOUD Partner
Message Center
Security & Compliance
Security Technologies and Applications
Web Application Firewall
Host Security Service
Cloud Firewall
SecMaster
Anti-DDoS Service
Data Encryption Workshop
Database Security Service
Cloud Bastion Host
Data Security Center
Cloud Certificate Manager
Edge Security
Managed Threat Detection
Blockchain
Blockchain Service
Web3 Node Engine Service
Media Services
Media Processing Center
Video On Demand
Live
SparkRTC
MetaStudio
Storage
Object Storage Service
Elastic Volume Service
Cloud Backup and Recovery
Storage Disaster Recovery Service
Scalable File Service Turbo
Scalable File Service
Volume Backup Service
Cloud Server Backup Service
Data Express Service
Dedicated Distributed Storage Service
Containers
Cloud Container Engine
SoftWare Repository for Container
Application Service Mesh
Ubiquitous Cloud Native Service
Cloud Container Instance
Databases
Relational Database Service
Document Database Service
Data Admin Service
Data Replication Service
GeminiDB
GaussDB
Distributed Database Middleware
Database and Application Migration UGO
TaurusDB
Middleware
Distributed Cache Service
API Gateway
Distributed Message Service for Kafka
Distributed Message Service for RabbitMQ
Distributed Message Service for RocketMQ
Cloud Service Engine
Multi-Site High Availability Service
EventGrid
Dedicated Cloud
Dedicated Computing Cluster
Business Applications
Workspace
ROMA Connect
Message & SMS
Domain Name Service
Edge Data Center Management
Meeting
AI
Face Recognition Service
Graph Engine Service
Content Moderation
Image Recognition
Optical Character Recognition
ModelArts
ImageSearch
Conversational Bot Service
Speech Interaction Service
Huawei HiLens
Video Intelligent Analysis Service
Developer Tools
SDK Developer Guide
API Request Signing Guide
Terraform
Koo Command Line Interface
Content Delivery & Edge Computing
Content Delivery Network
Intelligent EdgeFabric
CloudPond
Intelligent EdgeCloud
Solutions
SAP Cloud
High Performance Computing
Developer Services
ServiceStage
CodeArts
CodeArts PerfTest
CodeArts Req
CodeArts Pipeline
CodeArts Build
CodeArts Deploy
CodeArts Artifact
CodeArts TestPlan
CodeArts Check
CodeArts Repo
Cloud Application Engine
MacroVerse aPaaS
KooMessage
KooPhone
KooDrive

ALM-18022 Insufficient Yarn Queue Resources

Updated on 2022-08-12 GMT+08:00

Description

The alarm module checks Yarn queue resources every 60 seconds. This alarm is generated when available resources or ApplicationMaster (AM) resources of a queue are insufficient.

This alarm is cleared when available resources are sufficient.

Attribute

Alarm ID

Alarm Severity

Auto Clear

18022

Minor

Yes

Parameters

Parameter Name

Description

Source

Specifies the cluster for which the alarm is generated.

QueueName

Specifies the queue for which the alarm is generated.

QueueMetric

Specifies the metric of the queue for which the alarm is generated.

Trigger Condition

Specifies the threshold triggering the alarm. If the current indicator value exceeds this threshold, the alarm is generated.

Impact on the System

  • An application being executed takes longer time.
  • An application fails to be executed for a long time after being submitted.

Possible Causes

  • NodeManager node resources are insufficient.
  • The configured maximum resource capacity of the queue is excessively small.
  • The configured maximum AM resource percentage is excessively small.

Procedure

View alarm details.

  1. On the FusionInsight Manager, choose O&M > Alarm > Alarms.
  2. View location information of this alarm and check whether QueueName is root and QueueMetric is Memory or QueueName is root and QueueMetric is vCores.

    • If yes, go to 3.
    • If no, go to 4.

  1. The memory or CPU of the Yarn cluster is insufficient. In this case, log in to the node where NodeManager resides and run the free -g and cat /proc/cpuinfo commands to query the available memory and available CPU of the node, respectively. On FusionInsight Manager, increase the values of yarn.nodemanager.resource.memory-mb and yarn.nodemanager.resource.cpu-vcores for the Yarn NodeManager based on the query results. Then, restart the NodeManager instance. Check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 9.

  1. If QueueName is <Tenant Queue> and QueueMetric is Memory, or QueueName is <Tenant Queue> and QueueMetric is vCores in Location, check whether available Memory = or available vCores = are included in Additional Information.

    • If yes, go to 5.
    • If no, go to 7.

  1. The memory or CPU of the tenant queue is insufficient. In this case, choose Tenant Resources > Dynamic Resource Plan > Resource Distribution Policy and increase the value of Maximum Capacity. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  1. Choose Cluster > Name of the desired cluster > Services > Yarn > Configurations > All Configurations. Enter the keyword "threshold" and click ResourceManager. Adjust the threshold values of the following parameters:

    If Additional Information contains available Memory =, change the value of yarn.queue.memory.alarm.threshold to a value smaller than that of available Memory = in Additional Information.

    If Additional Information contains available vCores =, change the value of yarn.queue.vcore.alarm.threshold to a value smaller than that of available vCores = in Additional Information.

    Wait for five minutes and check whether the alarm is cleared.
    • If yes, no further action is required.
    • If no, go to 9.

  2. If available AmMemory = or available AmvCores = is included in Additional Information, ApplicationMaster memory or CPU of the tenant queue is insufficient. In this case, choose Tenant Resources > Dynamic Resource Plan > Queue Configuration and increase the value of Maximum Am Resource Percent. Then, check whether this alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 8.

  3. Choose Cluster > Name of the desired cluster > Services > Yarn > Configurations > All Configurations. Enter the keyword "threshold" and click ResourceManager. Adjust the threshold values of the following parameters:

    If Additional Information contains available AmMemory =, change the value of yarn.queue.memory.alarm.threshold to a value smaller than that of available AmMemory = in Additional Information.

    If Additional Information contains available AmvCores =, change the value of yarn.queue.vcore.alarm.threshold to a value smaller than that of available AmvCores = in Additional Information.

    Wait for five minutes and check whether the alarm is cleared.
    • If yes, no further action is required.
    • If no, go to 9.

Collect fault information.

  1. Log in to FusionInsight Manager of the active cluster, and choose O&M > Log > Download.
  2. Select Yarn in the required cluster from the Service.
  3. Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact the O&M personnel and send the collected logs.

Alarm Clearing

After the fault is rectified, the system automatically clears this alarm.

Reference

None

We use cookies to improve our site and your experience. By continuing to browse our site you accept our cookie policy. Find out more

Feedback

Feedback

Feedback

0/500

Selected Content

Submit selected content with the feedback