Compute
Elastic Cloud Server
Huawei Cloud Flexus
Bare Metal Server
Auto Scaling
Image Management Service
Dedicated Host
FunctionGraph
Cloud Phone Host
Huawei Cloud EulerOS
Networking
Virtual Private Cloud
Elastic IP
Elastic Load Balance
NAT Gateway
Direct Connect
Virtual Private Network
VPC Endpoint
Cloud Connect
Enterprise Router
Enterprise Switch
Global Accelerator
Management & Governance
Cloud Eye
Identity and Access Management
Cloud Trace Service
Resource Formation Service
Tag Management Service
Log Tank Service
Config
OneAccess
Resource Access Manager
Simple Message Notification
Application Performance Management
Application Operations Management
Organizations
Optimization Advisor
IAM Identity Center
Cloud Operations Center
Resource Governance Center
Migration
Server Migration Service
Object Storage Migration Service
Cloud Data Migration
Migration Center
Cloud Ecosystem
KooGallery
Partner Center
User Support
My Account
Billing Center
Cost Center
Resource Center
Enterprise Management
Service Tickets
HUAWEI CLOUD (International) FAQs
ICP Filing
Support Plans
My Credentials
Customer Operation Capabilities
Partner Support Plans
Professional Services
Analytics
MapReduce Service
Data Lake Insight
CloudTable Service
Cloud Search Service
Data Lake Visualization
Data Ingestion Service
GaussDB(DWS)
DataArts Studio
Data Lake Factory
DataArts Lake Formation
IoT
IoT Device Access
Others
Product Pricing Details
System Permissions
Console Quick Start
Common FAQs
Instructions for Associating with a HUAWEI CLOUD Partner
Message Center
Security & Compliance
Security Technologies and Applications
Web Application Firewall
Host Security Service
Cloud Firewall
SecMaster
Anti-DDoS Service
Data Encryption Workshop
Database Security Service
Cloud Bastion Host
Data Security Center
Cloud Certificate Manager
Edge Security
Managed Threat Detection
Blockchain
Blockchain Service
Web3 Node Engine Service
Media Services
Media Processing Center
Video On Demand
Live
SparkRTC
MetaStudio
Storage
Object Storage Service
Elastic Volume Service
Cloud Backup and Recovery
Storage Disaster Recovery Service
Scalable File Service Turbo
Scalable File Service
Volume Backup Service
Cloud Server Backup Service
Data Express Service
Dedicated Distributed Storage Service
Containers
Cloud Container Engine
SoftWare Repository for Container
Application Service Mesh
Ubiquitous Cloud Native Service
Cloud Container Instance
Databases
Relational Database Service
Document Database Service
Data Admin Service
Data Replication Service
GeminiDB
GaussDB
Distributed Database Middleware
Database and Application Migration UGO
TaurusDB
Middleware
Distributed Cache Service
API Gateway
Distributed Message Service for Kafka
Distributed Message Service for RabbitMQ
Distributed Message Service for RocketMQ
Cloud Service Engine
Multi-Site High Availability Service
EventGrid
Dedicated Cloud
Dedicated Computing Cluster
Business Applications
Workspace
ROMA Connect
Message & SMS
Domain Name Service
Edge Data Center Management
Meeting
AI
Face Recognition Service
Graph Engine Service
Content Moderation
Image Recognition
Optical Character Recognition
ModelArts
ImageSearch
Conversational Bot Service
Speech Interaction Service
Huawei HiLens
Video Intelligent Analysis Service
Developer Tools
SDK Developer Guide
API Request Signing Guide
Terraform
Koo Command Line Interface
Content Delivery & Edge Computing
Content Delivery Network
Intelligent EdgeFabric
CloudPond
Intelligent EdgeCloud
Solutions
SAP Cloud
High Performance Computing
Developer Services
ServiceStage
CodeArts
CodeArts PerfTest
CodeArts Req
CodeArts Pipeline
CodeArts Build
CodeArts Deploy
CodeArts Artifact
CodeArts TestPlan
CodeArts Check
CodeArts Repo
Cloud Application Engine
MacroVerse aPaaS
KooMessage
KooPhone
KooDrive

Communication Library Parameters

Updated on 2022-08-16 GMT+08:00

This section describes parameter settings and value ranges for communication libraries.

comm_tcp_mode

Parameter description: Specifies whether the communication library uses the TCP or SCTP protocol to set up a data channel. The modification of this parameter takes effect after the cluster is restarted.

Type: POSTMASTER

Value range: Boolean. If this parameter is set to on for CNs, the CNs connect to DNs using TCP. If this parameter is set to on for DNs, the DNs communicate with each other using TCP.

Default value: on

comm_sctp_port

Parameter description: Specifies the TCP or SCTP listening port used by the TCP proxy communication library or SCTP communication library, respectively.

Type: POSTMASTER

NOTICE:

This port number is automatically allocated during cluster deployment. Do not change the parameter setting. If the port number is incorrectly set, the database communication fails.

Value range: an integer ranging from 0 to 65535

Default value: port + Number of primary DNs on the local host x 2 + Sequence number of the local DN on the local host

comm_control_port

Parameter description: Specifies the TCP listening port used by the TCP proxy communication library or SCTP communication library, respectively.

Type: POSTMASTER

Value range: an integer ranging from 0 to 65535

Default value: port + Number of primary DNs on the local host x 2 + Sequence number of the local DN on the local host + 1

NOTICE:

This port number is automatically allocated during cluster deployment. Do not change the parameter setting. If the port number is incorrectly set, the database communication fails.

comm_max_datanode

Parameter description: Specifies the maximum number of DNs supported by the TCP proxy communication library or SCTP communication library.

Type: USERSET

Value range: an integer ranging from 1 to 8192

Default value: actual number of DNs

comm_max_stream

Parameter description: Specifies the maximum number of concurrent data streams supported by the TCP proxy communication library or SCTP communication library. The value of this parameter must be greater than: Number of concurrent data streams x Number of operators in each stream x Square of SMP.

Type: POSTMASTER

Value range: an integer ranging from 1 to 60000

Default value: calculated by the following formula: min (query_dop_limit x query_dop_limit x 2 x 20, max_process_memory (bytes) x 0.005/(Maximum number of CNs + Number of current DNs)/260. If the value is less than 1024, 1024 is used. query_dop_limit = Number of CPU cores of a single server/Number of DNs of a single server.

NOTE:
  • You are not advised to set this parameter to a large value because this will cause high memory usage (256 bytes x comm_max_stream x comm_max_datanode). If the number of concurrent data streams is large, the query is complex and the smp is large, resulting in insufficient memory.
  • If the value of comm_max_datanode is small, the process memory is sufficient. In this case, you can increase the value of comm_max_stream.

comm_max_receiver

Parameter description: Specifies the maximum number of receiving threads for the TCP proxy communication library or SCTP communication library.

Type: POSTMASTER

Value range: an integer ranging from 1 to 50

Default value: 4

comm_quota_size

Parameter description: Specifies the maximum size of packets that can be consecutively sent by the TCP proxy communication library or SCTP communication library. When you use a 1GE NIC, a small value ranging from 20 KB to 40 KB is recommended.

Type: USERSET

Value range: an integer ranging from 0 to 102400. The default unit is KB. The value 0 indicates that the quota mechanism is not used.

Default value: 1MB

comm_usable_memory

Parameter description: Specifies the maximum memory available for buffering on the TCP proxy communication library or SCTP communication library on a single DN.

Type: POSTMASTER

Value range: an integer ranging from 102400 to INT_MAX/2. The default unit is KB. The minimum size cannot be less than 1 GB for installation.

Default value: max_process_memory/8

NOTICE:

This parameter must be specifically set based on environment memory and the deployment method. If it is too large, there may be out-of-memory (OOM). If it is too small, the performance of the TCP proxy communication library or SCTP communication library may deteriorate.

comm_memory_pool_percent

Parameter description: Specifies the percentage of the memory pool resources that can be used by the TCP proxy communication library or the SCTP communication library in a DN. This parameter is used to adaptively reserve memory used by the communication libraries.

Type: POSTMASTER

Value range: an integer ranging from 0 to 100

Default value: 0

NOTICE:

If the memory used by the communication library is small, set this parameter to a small value. Otherwise, set it to a large value.

comm_client_bind

Parameter description: Specifies whether to bind the client of the communication library to a specified IP address when the client initiates a connection.

Type: USERSET

Value range: Boolean

  • on indicates that the client is bound to a specified IP address.
  • off indicates that the client is not bound to any IP addresses.
NOTICE:

If multiple IP addresses of a node in a cluster are on the same communication network segment, set this parameter to on. In this case, the client is bound to the IP address specified by listen_addresses. The concurrency performance of a cluster depends on the number of random ports because a port can be used only by one client at a time.

Default value: off

comm_no_delay

Parameter description: Specifies whether to use the NO_DELAY attribute of the communication library connection. Restart the cluster for the setting to take effect.

Type: USERSET

Value range: Boolean

Default value: off

NOTICE:

If packet loss occurs because a large number of packets are received per second, set this parameter to off to reduce the total number of packets.

comm_debug_mode

Parameter description: Specifies the debug mode of the TCP proxy communication library or SCTP communication library, that is, whether to print logs about the communication layer. The setting is effective at the session layer.

NOTICE:

When the switch is set to on, the number of printed logs is huge, adding extra overhead and reducing database performance. Therefore, set the switch to on only in the debug mode.

Type: USERSET

Value range: Boolean

  • on indicates the detailed debug log of the communication library is printed.
  • off indicates the detailed debug log of the communication library is not printed.

Default value: off

comm_ackchk_time

Parameter description: Specifies the duration after which the communication library server automatically triggers ACK when no data package is received.

Type: USERSET

Value range: an integer ranging from 0 to 20000. The unit is millisecond (ms). 0 indicates that automatic ACK triggering is disabled.

Default value: 2000

comm_timer_mode

Parameter description: Specifies the timer mode of the TCP proxy communication library or SCTP communication library, that is, whether to print timer logs in each phase of the communication layer. The setting is effective at the session layer.

NOTICE:

When the switch is set to on, the number of printed logs is huge, adding extra overhead and reducing database performance. Therefore, set the switch to on only in the debug mode.

Type: USERSET

Value range: Boolean

  • on indicates the detailed timer log of the communication library is printed.
  • off indicates the detailed timer log of the communication library is not printed.

Default value: off

comm_stat_mode

Parameter description: Specifies the statistics mode of the TCP proxy communication library or SCTP communication library, that is, whether to print statistics about the communication layer. The setting is effective at the session layer.

NOTICE:

When the switch is set to on, the number of printed logs is huge, adding extra overhead and reducing database performance. Therefore, set the switch to on only in the debug mode.

Type: USERSET

Value range: Boolean

  • on indicates the statistics log of the communication library is printed.
  • off indicates the statistics log of the communication library is not printed.

Default value: off

enable_stateless_pooler_reuse

Parameter description: Specifies whether to enable the pooler reuse mode. The setting takes effect after the cluster is restarted.

Type: POSTMASTER

Value range: Boolean

  • on or true indicates that the pooler reuse mode is enabled.
  • off or false indicates that the pooler reuse mode is disabled.
    NOTICE:

    Set this parameter to the same value for CNs and DNs. If enable_stateless_pooler_reuse is set to off for CNs and set to on for DNs, the cluster communication fails. Restart the cluster to make the setting take effect.

Default value: off

comm_cn_dn_logic_conn

Parameter description: Specifies a switch for logical connections between CNs and DNs. The parameter setting takes effect only after the cluster is restarted.

Type: POSTMASTER

Value range: Boolean

  • on or true indicates that the connections between CNs and DNs are logical, with the libcomm component in use.
  • off or false indicates that the connections between CNs and DNs are physical, with the libpq component in use.
    NOTICE:

    If comm_cn_dn_logic_conn is set to off for CNs and set to on for DNs, cluster communication will fail. You are advised to set this parameter to the same value for all CNs and DNs. Restart the cluster to make the setting take effect.

Default value: off