Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ V200 LSW Alarms/ ALM-3276800059 The port works in full duplex mode
Updated on 2024-01-25 GMT+08:00

ALM-3276800059 The port works in full duplex mode

Description

SRM/4/HALFDUPLEXCLEAR: OID [OID] The port works in full duplex mode. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalName=[OCTET],RelativeResource=[OCTET])

The interface working mode changed to full duplex.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800059

Warning

Communication alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

EntityPhysicalIndex

Indicates the interface index.

BaseTrapSeverity

Indicates the alarm severity.

BaseTrapProbableCause

Indicates the alarm cause.

BaseTrapEventType

Indicates the alarm type.

EntPhysicalName

Indicates the interface name.

RelativeResource

Indicates the relative resource.

Impact on the System

The interface alternates between Up and Down states.

Possible Causes

The interface begins to work in half duplex mode. When the interface works in full duplex mode, a full duplex alarm is generated.

Procedure

  1. Check whether the duplex state of the interface is correct according to networking requirements.

    Run the display interface interface-type [ interface-number ] command to check the duplex state of the interface.

    • If the duplex state of the interface is incorrect, modify the interface configuration.
    • If the duplex state of the interface is correct, go to step 2.

  2. End.