Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ V200 LSW Alarms/ ALM-3276800009 Indicates that power abnormal 67966
Updated on 2024-01-25 GMT+08:00

ALM-3276800009 Indicates that power abnormal 67966

Description

SRM/1/POWERFAULT: OID [OID] Power is abnormal. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalContainedIn=[INTEGER], EntPhysicalName=[OCTET], RelativeResource=[OCTET], ReasonDescription=[OCTET])

The power module is faulty.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800009

Critical

Equipment alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

EntityPhysicalIndex

Indicates the index of the physical entity.

BaseTrapSeverity

Indicates the severity level.

BaseTrapProbableCause

Indicates the error code.

BaseTrapEventType

Indicates the event type.

EntPhysicalContainedIn

Indicates the code of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

RelativeResource

Indicates the sub-entity.

ReasonDescription

Indicates the fault description.

Impact on the System

The device cannot receive sufficient power supply.

Possible Causes

  • The power module is powered off.
  • The power module does not load the correct electronic label.

Procedure

Power on the power module. If the alarm is not cleared, replace the power module.

Related Information

None