ALM-3276800008 Indicates that power loss 67967
Description
SRM/3/POWERABSENT: OID [OID] Power is absent. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalContainedIn=[INTEGER], EntPhysicalName=[OCTET], RelativeResource=[OCTET], ReasonDescription=[OCTET])
The power supply unit of a device is removed.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
3276800008 |
Minor |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
BaseTrapSeverity |
Indicates the severity level. |
BaseTrapProbableCause |
Indicates the error code: 67967. |
BaseTrapEventType |
Indicates the event type. |
EntPhysicalContainedIn |
Indicates the code of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity. |
RelativeResource |
Indicates the sub-entity. |
ReasonDescription |
Indicates the fault description. |
Impact on the System
If the device uses only one power supply, the device is powered off after the power supply is removed and services are interrupted.
Possible Causes
- The internal power module encounters a power failure.
- The internal power module is removed.
- The lead-acid battery is removed.
Procedure
Install the power supply.