ALM-3276800004 A Fan Module Does Not Work Properly
Description
SRM/3/ENTITYINVALID: OID [OID] Fan loss. (EntityPhysicalIndex[INTEGER1], BaseTrapSeverity=[INTEGER2], BaseTrapProbableCause=[INTEGER3], BaseTrapEventType=[INTEGER4], EntPhysicalContainedIn=[INTEGER5], EntPhysicalName=[OCTET1], RelativeResource=[OCTET2], ReasonDescription=[OCTET3])
A fan module does not work normally.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
3276800004 |
Minor |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
EntityPhysicalIndex |
Entity index. |
BaseTrapSeverity |
Severity code. |
BaseTrapProbableCause |
Error Code. |
BaseTrapEventType |
Code of the event type. |
EntPhysicalContainedIn |
Entity code. |
EntPhysicalName |
Entity name. |
RelativeResource |
Name of the affected component. |
ReasonDescription |
Fault description. |
Impact on the System
When the fan module fails to work normally, card temperature will increase, which may result in packet loss or even more seriously, failure of the switch to respond or unexpected restart.
Possible Causes
The cable of the fan module was connected loosely or the fan hardware was faulty.
Procedure
- Remove and insert the fan module and check whether the fault is rectified.
(1) If the fault persists, the fan hardware is faulty. In this case, replace the fan module.
(2) If the fault is rectified, go to Step 2.
- End.