Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ WAC&AP Alarms/ ALM-303046943 A Port Detects A PD Whose Current Exceeds the Threshold of the Corresponding Class.
Updated on 2024-01-25 GMT+08:00

ALM-303046943 A Port Detects A PD Whose Current Exceeds the Threshold of the Corresponding Class.

Description

WLAN/4/AP_POE_PD_CLASS_OVER_CURRENT:OID [OID] A port detects a PD whose current exceeds the threshold of the corresponding class. (APMAC=[OPAQUE], APName=[STRING], ApIfIndex=[INTEGER], ApEntityPhysicalName=[OCTET], APID=[INTEGER])

The system detects that overcurrent occurs during PD classification and does not provide power for PDs.

Only the AP4050DN-E, AP4050DN-HD, AP7050DN-E, AP7052DN, AP7152DN, AD9430DN-24, AD9431DN-24X and AD9430DN-12 support this alarm.

Attribute

Alarm ID

Alarm Severity

Alarm Type

303046943

Warning

Communication alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

APMAC

Indicates the AP's MAC address.

APName

Indicates the AP name.

ApIfIndex

Indicates the AP interface index.

ApEntityPhysicalName

Indicates the AP interface name.

APID

Indicates the AP ID.

Impact on the System

Services are not affected.

Possible Causes

The PD does not comply with standards.

Procedure

  1. You can run the poe high-inrush enable (AP system profile view) command in the AP system profile view to configure an interface to allow generation of the high pulse current. Then check whether the alarm is cleared.

    • If yes, go to step 4.
    • If not, go to step 2.

  2. Replace the PD and check whether the alarm is cleared.

    • If yes, go to step 4.
    • If not, go to step 3.

  3. Contact technical support personnel.
  4. End.

Related Information

None