Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ WAC&AP Alarms/ ALM-303046917 Some Functions on the Card Were Invalid
Updated on 2024-01-25 GMT+08:00

ALM-303046917 Some Functions on the Card Were Invalid

Description

ENTITYTRAP/2/BOARDFAIL: OID [OID] Board become failure for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

Some functions on the card are invalid.

Attribute

Alarm ID

Alarm Severity

Alarm Type

303046917

Major

equipmentAlarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm

Index

Indicates the entity index.

EntityPhysicalIndex

Indicates the physical entity index.

PhysicalName

Indicates the name of the physical entity.

EntityTrapEntType

Indicates the type of the physical entity, such as mpu(1), and lpu(2).

EntityTrapFaultID

Indicates the error code.

EntityTrapReasonDescr

Indicates the description of the alarm cause.

Impact on the System

The card is unavailable or some services are interrupted.

Possible Causes

Error Code

Possible Cause

132643

The Bluetooth function failed.

132642

The Reset button is faulty.

132641

The dual-edge connector is faulty.

132640

The CPU is faulty.

132623

The NP chip is faulty.

132103

The voltage failed.

132620

The power supply is faulty.

132619

The corrosion protection circuit is faulty.

132618

An overall fault occurs on the NP chip.

132149

The bad block rate for the NAND flash exceeds the threshold.

2125827

The temperature sensor is abnormal.

132865

The RTC was abnormal.

NOTE:

When the RTC is faulty, the system time may be incorrect after the device is restarted. However, services indifferent to system timing are not affected. If an NTP server is available on the network, the system time will be corrected after you enable the NTP client function on the device.

132146

The PSE power supply is faulty.

132121

The current on the USB flash drive exceeds the upper limit.

Procedure (AC device)

  1. Check whether the faulty card is registered successfully and services are running properly.

    Run the display device command to check whether the faulty card is registered successfully, and run the display interface command to view the statistics on received and sent packets. According to the statistics, check whether services are running properly.

    • If the faulty card is registered successfully and services are running properly, no further action is required.
    • If the faulty card is unregistered or services are not running properly, go to step 2.

  2. If the faulty card is a main control board, run the reboot command to reboot the device. Then check whether the device is working properly.

    • If the card can be registered successfully and services are running properly, no further action is required.
    • If the card cannot be registered or services cannot run properly, the card hardware is faulty. Replace this card.
    • If the fault persists, go to step 3.

  3. Contact technical support engineers.

Procedure (Cloud AP device)

  1. Check whether the faulty card is registered successfully and services are running properly.

    Run the display interface command to view the statistics on received and sent packets. According to the statistics, check whether services are running properly.

    • If the faulty card is registered successfully and services are running properly, no further action is required.
    • If the faulty card is unregistered or services are not running properly, go to step 2.

  2. If the faulty card is a main control board, run the reboot command to reboot the device. Then check whether the device is working properly.

    • If the card can be registered successfully and services are running properly, no further action is required.
    • If the card cannot be registered or services cannot run properly, the card hardware is faulty. Replace this card.
    • If the fault persists, go to step 3.

  3. Contact technical support engineers.

Related Information