ALM-303046917 Some Functions on the Card Were Invalid
Description
ENTITYTRAP/2/BOARDFAIL: OID [OID] Board become failure for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")
Some functions on the card are invalid.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046917 |
Major |
equipmentAlarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm |
Index |
Indicates the entity index. |
EntityPhysicalIndex |
Indicates the physical entity index. |
PhysicalName |
Indicates the name of the physical entity. |
EntityTrapEntType |
Indicates the type of the physical entity, such as mpu(1), and lpu(2). |
EntityTrapFaultID |
Indicates the error code. |
EntityTrapReasonDescr |
Indicates the description of the alarm cause. |
Impact on the System
The card is unavailable or some services are interrupted.
Possible Causes
Error Code |
Possible Cause |
---|---|
132643 |
The Bluetooth function failed. |
132642 |
The Reset button is faulty. |
132641 |
The dual-edge connector is faulty. |
132640 |
The CPU is faulty. |
132623 |
The NP chip is faulty. |
132103 |
The voltage failed. |
132620 |
The power supply is faulty. |
132619 |
The corrosion protection circuit is faulty. |
132618 |
An overall fault occurs on the NP chip. |
132149 |
The bad block rate for the NAND flash exceeds the threshold. |
2125827 |
The temperature sensor is abnormal. |
132865 |
The RTC was abnormal.
NOTE:
When the RTC is faulty, the system time may be incorrect after the device is restarted. However, services indifferent to system timing are not affected. If an NTP server is available on the network, the system time will be corrected after you enable the NTP client function on the device. |
132146 |
The PSE power supply is faulty. |
132121 |
The current on the USB flash drive exceeds the upper limit. |
Procedure (AC device)
- Check whether the faulty card is registered successfully and services are running properly.
Run the display device command to check whether the faulty card is registered successfully, and run the display interface command to view the statistics on received and sent packets. According to the statistics, check whether services are running properly.
- If the faulty card is registered successfully and services are running properly, no further action is required.
- If the faulty card is unregistered or services are not running properly, go to step 2.
- If the faulty card is a main control board, run the reboot command to reboot the device. Then check whether the device is working properly.
- If the card can be registered successfully and services are running properly, no further action is required.
- If the card cannot be registered or services cannot run properly, the card hardware is faulty. Replace this card.
- If the fault persists, go to step 3.
- Contact technical support engineers.
Procedure (Cloud AP device)
- Check whether the faulty card is registered successfully and services are running properly.
Run the display interface command to view the statistics on received and sent packets. According to the statistics, check whether services are running properly.
- If the faulty card is registered successfully and services are running properly, no further action is required.
- If the faulty card is unregistered or services are not running properly, go to step 2.
- If the faulty card is a main control board, run the reboot command to reboot the device. Then check whether the device is working properly.
- If the card can be registered successfully and services are running properly, no further action is required.
- If the card cannot be registered or services cannot run properly, the card hardware is faulty. Replace this card.
- If the fault persists, go to step 3.
- Contact technical support engineers.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.