ALM-303046688 An Exception Occurred on the Card
Description
ENTITYTRAP/2/BOARDFAIL: OID [OID] Card become failure for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], EntityTrapEntType= [INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])
An exception occurred on the card.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046688 |
Critical |
equipmentAlarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object of the alarm. |
Index |
Indicates the entity index. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapEntType |
Indicates the entity type. |
PhysicalName |
Indicates the physical entity name. |
EntityTrapFaultID |
Indicates the error code. |
Impact on the System
The card is unavailable, or some services are interrupted.
Possible Causes
Error Code |
Possible Cause |
---|---|
132643 |
The Bluetooth function failed. |
132642 |
The Reset button is faulty. |
132641 |
The dual-edge connector is faulty. |
132640 |
The CPU is faulty. |
132623 |
The NP chip is faulty. |
132103 |
The voltage failed. |
132620 |
The power supply is faulty. |
132619 |
The corrosion protection circuit is faulty. |
132618 |
An overall fault occurs on the NP chip. |
132149 |
The bad block rate for the NAND flash exceeds the threshold. |
2125827 |
The temperature sensor is abnormal. |
132865 |
The RTC was abnormal.
NOTE:
When the RTC is faulty, the system time may be incorrect after the device is restarted. However, services indifferent to system timing are not affected. If an NTP server is available on the network, the system time will be corrected after you enable the NTP client function on the device. |
132146 |
The PSE power supply is faulty. |
132121 |
The current on the USB flash drive exceeds the upper limit. |
Procedure
- Check whether the card is reset or powered off, or services on the card are not running properly.
- If so, go to step 2.
- If not, go to step 3.
- Power off and then on the card. Check whether the card fails to be registered or the fault persists after the card is registered.
- If so, go to step 3.
- If not, go to step 4.
- Collect alarms, logs, and configurations, and then contact technical support engineers.