Updated on 2024-01-25 GMT+08:00

ALM-15795346 hwPoePdClassOvercurrent

Description

POE/4/PDCLASSOVERCURRENT: OID [oid] has detected an overcurrent PD in classification and power denied. (IfIndex=[INTEGER], Interface="[OCTET]")

Port has detected a classfication overcurrent PD and power denied.

Attribute

AlarmID

Alarm OID

Alarm Severity

Alarm Type

15795346

1.3.6.1.4.1.2011.5.25.195.40.11

Warning

Equipment alarm

Parameters

Name

Meaning

IfIndex

Indicates the index of the faulty port.

Interface

Indicates the faulty port name.

Impact on the System

Services are not affected.

Possible Causes

Cause 1:

The PD may not comply with standards, whereas the switch supports 802.3af and 802.3at. In this case, the PD class cannot be identified by the switch.

Cause 2:

The PD hardware is faulty.

Cause 3:

The PoE chip of the device is faulty.

Procedure

  1. Run the poe high-inrush enable slot slot-id command in the system view to allow high inrush current during power-on and then check whether the alarm is cleared.

    If so, the alarm handling ends.

    If not, go to step 2.

  2. Replace the PD with a standard PD and then check whether the alarm is cleared.

    If so, the alarm handling ends.

    If not, collect alarm information and configuration information, and then contact technical support personnel.

Related Information

None.